Selected article for: "positive sample and true positive"

Author: Rödel, Jürgen; Egerer, Renate; Suleyman, Aynur; Sommer-Schmid, Beatrice; Baier, Michael; Henke, Andreas; Edel, Birgit; Löffler, Bettina
Title: Use of the variplex(TM) SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
  • Cord-id: 2sjh17mw
  • Document date: 2020_8_31
  • ID: 2sjh17mw
    Snippet: BACKGROUND: Molecular assays based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) may be useful for rapid diagnosis of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) because of the easy performance and the option to bypass RNA extraction. OBJECTIVES: This study was designed to evaluate the clinical performance of the CE-labeled variplexTM real time SARS-CoV-2 RT-LAMP assay in comparison to commercial RT-PCRs. STUDY DESIGN: RNA extracted from pharyngea
    Document: BACKGROUND: Molecular assays based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) may be useful for rapid diagnosis of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) because of the easy performance and the option to bypass RNA extraction. OBJECTIVES: This study was designed to evaluate the clinical performance of the CE-labeled variplexTM real time SARS-CoV-2 RT-LAMP assay in comparison to commercial RT-PCRs. STUDY DESIGN: RNA extracted from pharyngeal swabs was tested by variplex™ RT-LAMP and Corman’s LightMix™ E gene RT-PCR as reference. Samples of respiratory secretions from Coronavirus infection disease (COVID-19) and negative control patients were analyzed by variplex™ without RNA extraction and tested in parallel with the Allplex™ and VIASURE BD MAX RT-PCRs. RESULTS: Using isolated RNA variplex™ RT-LAMP showed a sensitivity of 75% compared to LightMix E gene RT-PCR but contrary to the latter it produced no false-positive results. For the evaluation of samples from respiratory secretions concordance analysis showed only a moderate agreement between the variplex™ RT-LAMP conducted on unprocessed samples and Allplex™ and VIASURE RT-PCRs (Cohen’s κ ranging from 0.52-0.56). Using the approach to define a sample as true-positive when at least two assays gave a positive result the clinical sensitivities were as follows: 76.3% for variplex™, 84.2% for Allplex™ and 68.4% for VIASURE. However, when results of RT-PCR and RT-LAMP were combined diagnostic sensitivity was increased to 92-100%. CONCLUSION: The variplex RT-LAMP may serve as a rapid test to be combined with a RT-PCR assay to increase the diagnostic accuracy in patients with suspected COVID-19 infection.

    Search related documents:
    Co phrase search for related documents
    • accurate timely and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate timely and low number: 1
    • accurate timely and low sensitivity: 1, 2, 3
    • accurate timely diagnosis and acute infection: 1, 2, 3, 4, 5, 6
    • accurate timely diagnosis and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • accurate timely diagnosis and low number: 1
    • accurate timely diagnosis and low sensitivity: 1
    • acid amplification test and acute infection: 1, 2, 3, 4, 5, 6, 7
    • acid amplification test and acute infection detect: 1
    • acid amplification test and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acid amplification test and additional tool: 1
    • acid amplification test and low sensitivity: 1
    • acid extraction and acute infection: 1, 2, 3, 4, 5, 6, 7
    • acid extraction and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acid extraction and low number: 1
    • acid extraction and low sensitivity: 1
    • acute infection and additional tool: 1
    • acute infection and low number: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acute infection and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21