Author: Jeon, Seung Hyun; Jung, Saebin; Son, Hee-Seo; Kimm, Simon Y; Chung, Benjamin I
Title: The unidirectional barbed suture for renorrhaphy during laparoscopic partial nephrectomy: Stanford experience. Cord-id: co7siycu Document date: 2013_1_1
ID: co7siycu
Snippet: PURPOSE Using barbed suture represents a novel technical modification in the performance of minimally invasive partial nephrectomy. Our purpose of this study was to evaluate the safety and efficacy of this suture for renorrhaphy during laparoscopic partial nephrectomy (LPN). PATIENTS AND METHODS Thirteen consecutive patients underwent LPN using V-Locâ„¢ 180 (Covidien, Dublin, Ireland) suture, and a nonconsecutive control group of 24 patients, matched according to tumor size and R.E.N.A.L. nephro
Document: PURPOSE Using barbed suture represents a novel technical modification in the performance of minimally invasive partial nephrectomy. Our purpose of this study was to evaluate the safety and efficacy of this suture for renorrhaphy during laparoscopic partial nephrectomy (LPN). PATIENTS AND METHODS Thirteen consecutive patients underwent LPN using V-Loc™ 180 (Covidien, Dublin, Ireland) suture, and a nonconsecutive control group of 24 patients, matched according to tumor size and R.E.N.A.L. nephrometry score, underwent LPN using absorbable polyglactin suture. All 37 patients underwent LPN performed by a single surgeon. Perioperative and postoperative indicators of morbidity, estimated blood loss, and warm ischemia time (WIT) were compared between the groups. RESULTS Baseline characteristics including age, body mass index, American Society of Anesthesiologists score, tumor size, laterality, and R.E.N.A.L nephrometry score were identical between the groups. On multivariable analysis, there were no significant differences between the two groups with regard to operative time, estimated blood loss, transfusion rates, rates of surgical complications, and length of hospital stay. However, mean WIT was significantly shorter in the V-Loc group compared with the control group (24.5±5.3 minutes versus 31.9±8.9 minutes, P=.01). CONCLUSIONS The use of V-Loc sutures for renorrhaphy during LPN is safe and feasible and, in our series, significantly reduces WIT. Further studies are needed to corroborate these findings, but these results indicate a promising development in reducing WIT during minimally invasive partial nephrectomy.
Search related documents:
Co phrase search for related documents, hyperlinks ordered by date