Author: Grove, J. S.; Mayne, E. S.; Burgers, W. A.; Blackburn, J.; Jugwanth, S.; Stevens, W.; Scott, L.; David, A.; Gededzha, M.; Sanne, I. M.; Maphayi, M. R.; Pillay, T.; George, J. A.
Title: Validation of roche immunoassay for severe acute respiratory coronavirus 2 in South Africa Cord-id: 7mz01g70 Document date: 2021_1_1
ID: 7mz01g70
Snippet: Background: Serology testing is an important ancillary diagnostic to the reverse transcriptase polymerase chain reaction (RT-PCR) test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We aimed to evaluate the performance of the Roche Elecsysâ„¢ chemiluminescent immunoassay (Rotkreuz, Switzerland), that detects antibodies against the SARS-CoV-2 nucleocapsid antigen, at an academic laboratory in South Africa. Methods: Serum samples were collected from 312 donors with confirmed pos
Document: Background: Serology testing is an important ancillary diagnostic to the reverse transcriptase polymerase chain reaction (RT-PCR) test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We aimed to evaluate the performance of the Roche Elecsys™ chemiluminescent immunoassay (Rotkreuz, Switzerland), that detects antibodies against the SARS-CoV-2 nucleocapsid antigen, at an academic laboratory in South Africa. Methods: Serum samples were collected from 312 donors with confirmed positive SARS-CoV-2 RT-PCR tests, with approval from a large university’s human research ethics committee. Negative controls included samples stored prior to December 2019 and from patients who tested negative for SARS-CoV-2 on RT-PCR and were confirmed negative using multiple serology methods (n = 124). Samples were stored at –80 °C and analysed on a Roche cobas™ 602 autoanalyser. Results: Compared with RT-PCR, our evaluation revealed a specificity of 100% and overall sensitivity of 65.1%. The sensitivity in individuals > 14 days’ post-diagnosis was 72.6%, with the highest sensitivity 31–50 days’ post-diagnosis at 88.6%. Results were also compared with in-house serology tests that showed high agreement in majority of categories. Conclusions: The sensitivity at all-time points post-diagnosis was lower than reported in other studies, but sensitivity in appropriate cohorts approached 90% with a high specificity. The lower sensitivity at earlier time points or in individuals without symptomatology may indicate failure to produce antibodies, which was further supported by the comparison against in-house serology tests.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date