Author: Tréâ€Hardy, Marie; Wilmet, Alain; Beukinga, Ingrid; Favresse, Julien; Dogné, Jeanâ€Michel; Douxfils, Jonathan; Blairon, Laurent
Title: Analytical and clinical validation of an ELISA for specific SARSâ€CoVâ€2 IgG, IgA, and IgM antibodies Cord-id: dp4a25me Document date: 2020_7_27
ID: dp4a25me
Snippet: The development of severe acute respiratory syndrome coronavirus 2 (SARSâ€CoVâ€2) serological tests is massive. The external validation of their performance is needed before use in clinical routine practice. Our study aims at assessing the analytical and clinical performance of two enzymeâ€linked immunosorbent assay tests detecting antibodies directed against the virus nucleocapsid protein: The NovaLisa SARSâ€CoVâ€2 immunoglobulin G (IgG), immunoglobulin A (IgA), and immunoglobulin M (IgM)
Document: The development of severe acute respiratory syndrome coronavirus 2 (SARSâ€CoVâ€2) serological tests is massive. The external validation of their performance is needed before use in clinical routine practice. Our study aims at assessing the analytical and clinical performance of two enzymeâ€linked immunosorbent assay tests detecting antibodies directed against the virus nucleocapsid protein: The NovaLisa SARSâ€CoVâ€2 immunoglobulin G (IgG), immunoglobulin A (IgA), and immunoglobulin M (IgM) test (NovaTec) allowing a separate detection of each antibody and the Platelia SARSâ€CoVâ€2 Total Ab test (Bioâ€Rad) detecting total antibodies (IgM, IgA, and IgG). Twoâ€hundred and eight coronavirus disease 2019 samples from 48 quantitative reverse transcriptionâ€polymerase chain reaction (RTâ€qPCR) confirmed patients were used to perform the sensitivity analysis. Nonâ€SARSâ€CoVâ€2 sera (n = 79) with a potential crossâ€reaction to SARSâ€CoVâ€2 immunoassays were included in the specificity analysis. In addition, using receiver operator characteristic curves, adapted cutâ€off for improvement of the performances were proposed. The kinetics of these antibodies was also assessed over 8 weeks. Two weeks after the RTâ€qPCR positive detection, the NovaLisa test shows a sensitivity and specificity of 94.9% (95% confidence interval [CI]: 83.1%â€98.6%) and 96.2% (95% CI: 89.4%â€98.7%) for IgG, of 89.7% (95% CI: 76.4%â€95.9%) and 98.7% (95% CI: 93.2%â€98.8%) for IgA, and of 48.7% (95% CI: 33.9%â€63.8%) and 98.7% (95% CI: 93.2%â€99.8%) for IgM. With the Platelia system, the specificity and sensitivity were 97.4% (95% CI: 92.1%â€99.7%) and 94.9% (95% CI: 87.7%â€98.0%) for total antibodies using the adapted cutâ€offs. The NovaLisa and the Platelia tests have satisfactory analytical performances. The clinical performances are excellent for IgG, IgA, and total antibodies especially if the cutâ€off is optimized.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date