Selected article for: "absorption spectra and accurate detection"

Author: Tang, Wenzhi; Qi, Yangchun; Li, Zhonghong
Title: A Portable, Cost-Effective and User-Friendly Instrument for Colorimetric Enzyme-Linked Immunosorbent Assay and Rapid Detection of Aflatoxin B(1)
  • Cord-id: g05yvna4
  • Document date: 2021_10_17
  • ID: g05yvna4
    Snippet: Food analysis based on the enzyme-linked immunosorbent assay (ELISA) is simple, sensitive and rapid, but requires a costly colorimetric instrument. The aim of this work was to develop a portable, low-cost and user-friendly colorimetric instrument for colorimetric ELISA and aflatoxin B(1) (AFB(1)) detection. The principle of the developed instrument was employing a light-emitting diode to generate the signal light and using a light-dependent resistor to measure the signal light absorbed by the ox
    Document: Food analysis based on the enzyme-linked immunosorbent assay (ELISA) is simple, sensitive and rapid, but requires a costly colorimetric instrument. The aim of this work was to develop a portable, low-cost and user-friendly colorimetric instrument for colorimetric ELISA and aflatoxin B(1) (AFB(1)) detection. The principle of the developed instrument was employing a light-emitting diode to generate the signal light and using a light-dependent resistor to measure the signal light absorbed by the oxidized 3,3′,5,5′-tetramethyl benzidine. The absorption spectra revealed that the solution absorbed signal light more strongly after reaction with H(2)SO(4), and blue light would be favorably absorbed. Evaluations on the stability and accuracy of the instrument and interference from ambient light showed that the fabricated instrument was stable, accurate, capable of quantitative detection and insensitive to ambient light changes. In addition, this instrument is user-friendly since it could calculate and report the final amount of AFB(1) to the operator. Measurements of maize and peanuts showed that the instrument provided as accurate results as the professional equipment. With the low fabrication cost (about RMB 129 or USD 20), portability, and user-friendliness, this instrument presents attractive potential in the rapid detection of AFB(1).

    Search related documents:
    Co phrase search for related documents
    • lod detection limit and low cost quantitative: 1
    • lod detection limit and low cost rapid detection: 1, 2
    • lod detection limit and low cost simple: 1, 2, 3, 4
    • lod detection limit and low income: 1, 2, 3