Author: Park, Jeong Jin; Kim, Youngmi; Chai, Chung Liang; Jeon, Jin Pyeong
Title: Application of Near-Infrared Spectroscopy for the Detection of Delayed Cerebral Ischemia in Poor-Grade Subarachnoid Hemorrhage Cord-id: 3bz9dj5j Document date: 2021_5_7
ID: 3bz9dj5j
Snippet: BACKGROUND: The objective of this study was to investigate the clinical feasibility of near-infrared spectroscopy (NIRS) for the detection of delayed cerebral ischemia (DCI) in patients with poor-grade subarachnoid hemorrhage (SAH) treated with coil embolization. METHODS: Cerebral regional oxygen saturation (rSO(2)) was continuously monitored via two-channel NIRS for 14 days following SAH. The rSO(2) levels according to DCI were analyzed by using the Mann–Whitney U-test. A receiver operating c
Document: BACKGROUND: The objective of this study was to investigate the clinical feasibility of near-infrared spectroscopy (NIRS) for the detection of delayed cerebral ischemia (DCI) in patients with poor-grade subarachnoid hemorrhage (SAH) treated with coil embolization. METHODS: Cerebral regional oxygen saturation (rSO(2)) was continuously monitored via two-channel NIRS for 14 days following SAH. The rSO(2) levels according to DCI were analyzed by using the Mann–Whitney U-test. A receiver operating characteristic curve was generated on the basis of changes in rSO(2) by using the rSO(2) level on day 1 as a reference value to determine the optimal cutoff value for identifying DCI. RESULTS: Twenty-four patients with poor-grade SAH were included (DCI, n = 8 [33.3%]; non-DCI, n = 16 [66.7%]). The rSO(2) levels of patients with DCI were significantly lowered from 6 to 9 days compared with those in without DCI. The rSO(2) level was 62.55% (58.30–63.40%) on day 6 in patients with DCI versus 65.40% (60.90–68.70%) in those without DCI. By day 7, it was 60.40% (58.10–61.90%) in patients with DCI versus 64.25% (62.50–67.10%) those without DCI. By day 8, it was 58.90% (56.50–63.10%) in patients with DCI versus 66.05% (59.90–69.20%) in those without DCI, and by day 9, it was 60.85% (58.40–65.20%) in patients with DCI versus 65.80% (62.70–68.30%) in those without DCI. A decline of greater than 14.5% in the rSO(2) rate yielded a sensitivity of 92.86% (95% confidence interval: 66.1–99.8%) and a specificity of 88.24% (95% confidence interval: 72.5–96.7%) for identifying DCI. A decrease by more than 14.7% of the rSO(2) level indicates a sensitivity of 85.7% and a specificity of 85.7% for identifying DCI. CONCLUSIONS: Near-infrared spectroscopy shows some promising results for the detection of DCI in patients with poor-grade SAH. Further studies involving a large cohort of the SAH population are required to confirm our results. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12028-021-01223-2.
Search related documents:
Co phrase search for related documents- accurate early and magnetic resonance: 1, 2, 3, 4, 5
- accurate early diagnosis and magnetic resonance: 1, 2, 3, 4
Co phrase search for related documents, hyperlinks ordered by date