Author: Lilliu, Marzia; Onorati, Francesco; Luciani, Giovanni Battista; Faggian, Giuseppe
Title: Effects of echoâ€optimization of left ventricular assist devices on functional capacity, a randomized controlled trial Cord-id: gwlb9xba Document date: 2021_5_2
ID: gwlb9xba
Snippet: AIMS: After the implantation of a left ventricular assist device (LVAD), many patients continue to experience exercise intolerance. VAFRACT trial evaluates the additional benefit of LVAD echoâ€guided optimization (EO) on functional capacity (FC), measured by cardiopulmonary exercise test (CPET), and quality of life (QoL). METHODS AND RESULTS: Twentyâ€seven patients were randomized in a 1:1 ratio to EO (EO group) vs. standard settings (CONTROL group) at least after 3 months from LVAD implant pr
Document: AIMS: After the implantation of a left ventricular assist device (LVAD), many patients continue to experience exercise intolerance. VAFRACT trial evaluates the additional benefit of LVAD echoâ€guided optimization (EO) on functional capacity (FC), measured by cardiopulmonary exercise test (CPET), and quality of life (QoL). METHODS AND RESULTS: Twentyâ€seven patients were randomized in a 1:1 ratio to EO (EO group) vs. standard settings (CONTROL group) at least after 3 months from LVAD implant procedure. The optimal device speed was defined as the one that allows an intermittent aortic valve opening and a neutral position of the interventricular septum without increasing aortic or tricuspid regurgitation and preserving right ventricular function. The primary endpoint was peak oxygen uptake (VO(2) peak) change after 3 months. Echoâ€guided optimization significantly improves VO(2) peak (from 13.2 ± 2.5 to 14.2 ± 2.5 mL/kg/min; P < 0.001), oxygen pulse (from 9.75 ± 1.46 to 10.75 ± 2.2 mL; P < 0.001), CPET exercise time (from 490 ± 98 to 526 ± 116 s; P = 0.02), 6 min walk distance (from 363 ± 54 to 391 ± 52 m; P = 0.04), and QoL, using EuroQol Five Dimensions 3L (from 0.796 ± 0.1 to 0.85 ± 0.08; P < 0.001) and the Kansas City Cardiomyopathy Questionnaire (from 81.6 ± 6.9 to 84.6 ± 5.6; P = 0.025). CONCLUSIONS: Echoâ€guided optimization can significantly influence the FC and the QoL of LVAD patients. This procedure should represent a fundamental step in their clinical management, through the establishment of consolidated followâ€up protocols. Our study may represent a starting point for a future, adequately powered clinical trial with a longer term followâ€up.
Search related documents:
Co phrase search for related documents- active group and adequately powered: 1
- active group and liver function: 1
- additional benefit and live quality: 1
Co phrase search for related documents, hyperlinks ordered by date