Selected article for: "extraction step and high throughput"

Author: Fassy, Julien; Lacoux, Caroline; Leroy, Sylvie; Noussair, Latifa; Hubac, Sylvain; Degoutte, Aurélien; Vassaux, Georges; Leclercq, Vianney; Rouquié, David; Marquette, Charles-Hugo; Rottman, Martin; Touron, Patrick; Lemoine, Antoinette; Herrmann, Jean-Louis; Barbry, Pascal; Nahon, Jean-Louis; Zaragosi, Laure-Emmanuelle; Mari, Bernard
Title: Versatile and flexible microfluidic qPCR test for high-throughput SARS-CoV-2 and cellular response detection in nasopharyngeal swab samples
  • Cord-id: 8h8mezan
  • Document date: 2021_4_14
  • ID: 8h8mezan
    Snippet: The emergence and quick spread of SARS-CoV-2 has pointed at a low capacity response for testing large populations in many countries, in line of material, technical and staff limitations. The traditional RT-qPCR diagnostic test remains the reference method and is by far the most widely used test. These assays are limited to a few probe sets, require large sample PCR reaction volumes, along with an expensive and time-consuming RNA extraction step. Here we describe a quantitative nanofluidic assay
    Document: The emergence and quick spread of SARS-CoV-2 has pointed at a low capacity response for testing large populations in many countries, in line of material, technical and staff limitations. The traditional RT-qPCR diagnostic test remains the reference method and is by far the most widely used test. These assays are limited to a few probe sets, require large sample PCR reaction volumes, along with an expensive and time-consuming RNA extraction step. Here we describe a quantitative nanofluidic assay that overcomes some of these shortcomings, based on the Biomark(TM) instrument from Fluidigm. This system offers the possibility of performing 4608 qPCR end-points in a single run, equivalent to 192 clinical samples combined with 12 pairs of primers/probe sets in duplicate, thus allowing the monitoring of SARS-CoV-2 including the detection of specific SARS-CoV-2 variants, as well as the detection other pathogens and/or host cellular responses (virus receptors, response markers, microRNAs). The 10 nL-range volume of Biomark(TM) reactions is compatible with sensitive and reproducible reactions that can be easily and cost-effectively adapted to various RT-qPCR configurations and sets of primers/probe. Finally, we also evaluated the use of inactivating lysis buffers composed of various detergents in the presence or absence of proteinase K to assess the compatibility of these buffers with a direct reverse transcription enzymatic step and we propose several protocols, bypassing the need for RNA purification. We advocate that the combined utilization of an optimized processing buffer and a high-throughput real-time PCR device would contribute to improve the turn-around-time to deliver the test results to patients and increase the SARS-CoV-2 testing capacities.

    Search related documents:
    Co phrase search for related documents
    • absence presence and acute chronic: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
    • absence presence and adaptive immune activation: 1
    • absence presence and additional test: 1
    • acute ards respiratory distress syndrome and adaptive immune activation: 1, 2
    • acute ards respiratory distress syndrome and additional control: 1
    • acute chronic and adaptive immune activation: 1
    • acute chronic and additional control: 1, 2