Selected article for: "LAMP system and real time LAMP system"

Author: Deguo Wang
Title: One-pot Detection of COVID-19 with Real-time Reverse-transcription Loop-mediated Isothermal Amplification (RT-LAMP) Assay and Visual RT-LAMP Assay
  • Document date: 2020_4_22
  • ID: krim73zt_7
    Snippet: The effect of inhibitors in blood samples on the amplification efficiency had been determined, as Figure 2 indicated, when the real-time RT-LAMP reaction system was added with 10 µL blood samples dissolved in 10 µL 2019-nCoV-Fast-Sample Nucleic Acid Releasing Agent (Hunan Shengxiang Biology Technology Co., Ltd, China), there was no amplification; when 7.5 µL blood samples and 10 µL 2019-nCoV-Fast-Sample Nucleic Acid Releasing Agent added, the.....
    Document: The effect of inhibitors in blood samples on the amplification efficiency had been determined, as Figure 2 indicated, when the real-time RT-LAMP reaction system was added with 10 µL blood samples dissolved in 10 µL 2019-nCoV-Fast-Sample Nucleic Acid Releasing Agent (Hunan Shengxiang Biology Technology Co., Ltd, China), there was no amplification; when 7.5 µL blood samples and 10 µL 2019-nCoV-Fast-Sample Nucleic Acid Releasing Agent added, there was slight amplification; when 5µL or 2.5 µL blood samples dissolved in 10 µL 2019-nCoV-Fast-Sample Nucleic Acid Releasing Agent added, there was acceptable effect on the real-time RT-LAMP reaction. Therefore, the blood sample volume of 5µL was selected for 50 µL one-pot real-time or visual RT-LAMP reaction.

    Search related documents:
    Co phrase search for related documents
    • amplification efficiency and real time RT LAMP reaction: 1
    • amplification efficiency and RT LAMP reaction: 1
    • amplification efficiency and slight amplification: 1
    • blood sample and fast sample: 1, 2
    • blood sample and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • fast sample and reaction system: 1
    • fast sample and real time: 1, 2, 3, 4, 5
    • reaction system and real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23
    • reaction system and RT LAMP reaction: 1, 2, 3, 4, 5, 6
    • reaction system and RT LAMP reaction system: 1, 2, 3, 4, 5
    • reaction system and visual real time: 1
    • real time and RT LAMP reaction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19
    • real time and RT LAMP reaction system: 1, 2
    • real time and visual real time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • real time and visual real time RT LAMP reaction: 1
    • real time RT LAMP reaction and RT LAMP reaction: 1, 2, 3, 4, 5
    • real time RT LAMP reaction and visual real time: 1
    • real time RT LAMP reaction and visual real time RT LAMP reaction: 1
    • RT LAMP reaction and visual real time: 1, 2