Selected article for: "extracted template and InfA primer"

Author: Arunkumar Arumugam; Season S Wong
Title: The Potential Use of Unprocessed Sample for RT-qPCR Detection of COVID-19 without an RNA Extraction Step
  • Document date: 2020_4_8
  • ID: ka3n9pft_1
    Snippet: We first tested the feasibility using a very small amount of sample in RT-qPCR reactions by using aerosol generating vials to spray the samples over the uncapped PCR tubes. The material in vials containing influenza A (InfA), influenza B (InfB), or RSV clinical specimens (swabs in VTM) were sprayed into PCR tubes containing primer and probe sets targeting InfA, InfB, RSV and RNaseP (RP) in master mix prior to capping the tubes and performing RT-q.....
    Document: We first tested the feasibility using a very small amount of sample in RT-qPCR reactions by using aerosol generating vials to spray the samples over the uncapped PCR tubes. The material in vials containing influenza A (InfA), influenza B (InfB), or RSV clinical specimens (swabs in VTM) were sprayed into PCR tubes containing primer and probe sets targeting InfA, InfB, RSV and RNaseP (RP) in master mix prior to capping the tubes and performing RT-qPCR. Fig. 1 shows that there were positive PCR signals in the respective tubes that did not have any non-specific amplification. Though the unprocessed, sprayed samples have higher Ct values (36.5, 36.2 and 31 for InfA, InfB, and RSV, respectively) than the corresponding extracted RNA template samples (30.4, 32.6, 29.6 for InfA, InfB, and RSV). It is important to note that we were able to detect low viral load samples (Ct >30) when less than 1 µL of sample entered the tubes as measured by an analytical balance.

    Search related documents:
    Co phrase search for related documents
    • master mix and PCR tube: 1, 2, 3
    • master mix and probe primer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • master mix and RNA template sample: 1
    • master mix and RT qPCR reaction: 1, 2, 3, 4, 5
    • master mix and sample µL: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • master mix and sample small: 1, 2
    • master mix and template sample: 1, 2, 3
    • master mix and viral load: 1, 2
    • non specific amplification and probe primer: 1, 2, 3
    • non specific amplification and probe primer set: 1, 2
    • non specific amplification and sample µL: 1
    • PCR signal and probe primer: 1, 2
    • PCR signal and probe primer set: 1
    • PCR signal and sample small: 1
    • PCR tube and probe primer: 1, 2, 3, 4
    • PCR tube and RT qPCR reaction: 1, 2
    • PCR tube and sample µL: 1
    • PCR tube and tube cap: 1, 2
    • viral load and VTM swab: 1, 2, 3