Selected article for: "local tumour progression and magnetic resonance"

Author: Hoffmann, Rüdiger; Rempp, Hansjörg; Keßler, David-Emanuel; Weiß, Jakob; Pereira, Philippe L; Nikolaou, Konstantin; Clasen, Stephan
Title: MR-guided microwave ablation in hepatic tumours: initial results in clinical routine.
  • Cord-id: 9vo3b1ca
  • Document date: 2017_1_1
  • ID: 9vo3b1ca
    Snippet: OBJECTIVES Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. METHODS Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and
    Document: OBJECTIVES Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. METHODS Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and ablation zone diameters were assessed by post-ablative MR imaging. Technique effectiveness was assessed after 1 month. Complications were classified according to the Common Terminology Criteria for Adverse Events (CTCAE). Mean follow-up was 5.8 months ± 2.6 (1-10 months). RESULTS Technical success and technique effectiveness were achieved in all lesions. Lesions were treated using 2.5 ± 1.2 applicator positions. Mean energy and ablation duration per tumour were 37.6 kJ ± 21.7 (9-87 kJ) and 24.7 min ± 11.1 (7-49 min), respectively. Coagulation zone short- and long-axis diameters were 31.5 mm ± 10.5 (16-65 mm) and 52.7 mm ± 15.4 (27-94 mm), respectively. Two CTCAE-2-complications occurred (pneumothorax, pleural effusion). Seven patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed. CONCLUSIONS Microwave ablation is feasible under near real-time MR guidance and provides effective treatment of hepatic malignancies in one session. KEY POINTS • Planning, applicator placement and therapy monitoring are possible without using contrast enhancement • Energy transmission from the generator to the scanner room is safely possible • MR-guided microwave ablation provides effective treatment of hepatic malignancies in one session • Therapy monitoring is possible without applicator retraction from the ablation site.

    Search related documents:
    Co phrase search for related documents
    • ablation energy and magnetic resonance: 1
    • ablation site and magnetic resonance: 1, 2
    • ablation zone and local tumour progression: 1, 2
    • ablation zone and magnetic resonance: 1, 2, 3, 4, 5
    • ablation zone diameter and magnetic resonance: 1
    • ablative mr imaging and magnetic resonance: 1
    • local tumour progression and magnetic resonance: 1, 2