Selected article for: "failure rate and fit test"

Author: Wanner, Gregory K.; Ader, Douglas; Caplan, Richard; Padaki, Amit S.; Ravert, Debra; Drees, Marci
Title: Evaluation of N95 respirator ultraviolet decontamination and clinical reuse with quantitative fit testing
  • Cord-id: 6kyihv2z
  • Document date: 2021_5_3
  • ID: 6kyihv2z
    Snippet: The supply of N95 respirators has been severely strained by the coronavirus disease 2019 (COVID-19) pandemic. We used quantitative fit-testing to evaluate 16 participants and 45 respirators through up to 4 rounds of ultraviolet decontamination and clinical reuse. The mean fit-test failure rate was 29.7%, and the probability of failure increased through N95 reuse.
    Document: The supply of N95 respirators has been severely strained by the coronavirus disease 2019 (COVID-19) pandemic. We used quantitative fit-testing to evaluate 16 participants and 45 respirators through up to 4 rounds of ultraviolet decontamination and clinical reuse. The mean fit-test failure rate was 29.7%, and the probability of failure increased through N95 reuse.

    Search related documents: