Author: Wirth, S; Baur, M; Spaeth, J; Guttmann, J; Schumann, S
Title: Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile. Cord-id: ab4f0e4e Document date: 2015_1_1
ID: ab4f0e4e
Snippet: BACKGROUND Lung-protective mechanical ventilation during general surgery including the application of PEEP can reduce postoperative pulmonary complications. In a prospective clinical observation study, we evaluated volume-dependent respiratory system compliance in adult patients undergoing ear-nose-throat surgery with ventilation settings chosen empirically by the attending anaesthetist. METHODS In 40 patients, we measured the respiratory variables during intraoperative mechanical ventilation. A
Document: BACKGROUND Lung-protective mechanical ventilation during general surgery including the application of PEEP can reduce postoperative pulmonary complications. In a prospective clinical observation study, we evaluated volume-dependent respiratory system compliance in adult patients undergoing ear-nose-throat surgery with ventilation settings chosen empirically by the attending anaesthetist. METHODS In 40 patients, we measured the respiratory variables during intraoperative mechanical ventilation. All measurements were subdivided into 5 min intervals. Dynamic compliance (CRS) and the intratidal volume-dependent CRS curve was calculated for each interval and classified into one of the six specific compliance profiles indicating intratidal recruitment/derecruitment, overdistension or all. We retrospectively compared the occurrences of the respective compliance profiles at PEEP levels of 5 cm H2O and at higher levels. RESULTS The attending anaesthetists set the PEEP level initially to 5 cm H2O in 29 patients (83%), to 7 cm H2O in 5 patients (14%), and to 8 cm H2O in 2 patients (6%). Across all measurements the mean CRS was 61 (11) ml cm H2O(-1) (40-86 ml cm H2O(-1)) and decreased continuously during the procedure. At PEEP of 5 cm H2O the compliance profile indicating strong intratidal recruitment/derecruitment occurred more often (18.6%) compared with higher PEEP levels (5.5%, P<0.01). Overdistension was practically never observed. CONCLUSIONS In most patients, a PEEP of 5 cm H2O during intraoperative mechanical ventilation is too low to prevent intratidal recruitment/derecruitment. The analysis of the intratidal compliance profile provides the rationale to individually titrate a PEEP level that stabilizes the alveolar recruitment status of the lung during intraoperative mechanical ventilation. TRIAL REGISTRATION NUMBER DRKS00004286.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date