Author: Wang, Rui-huan; Zhang, Hong; Zhang, Yi; Li, Xin-na; Shen, Xin-xin; Qi, Ju-ju; Fan, Guo-hao; Xiang, Xing-yu; Zhan, Zhi-fei; Chen, Zi-wei; Ma, Xue-jun
Title: Development and evaluation of recombinase-aided amplification assays incorporating competitive internal controls for detection of human adenovirus serotypes 3 and 7 Cord-id: kt5f672s Document date: 2019_7_1
ID: kt5f672s
Snippet: BACKGROUND: Human adenoviruses are a common group of viruses that cause acute infectious diseases. Human adenovirus (HAdV) 3 and HAdV 7 cause major outbreaks of severe pneumonia. A reliable and practical method for HAdV typing in clinical laboratories is lacking. A simple, rapid and accurate molecular typing method for HAdV may facilitate clinical diagnosis and epidemiological control. METHODS: We developed and evaluated duplex real-time recombinase-aided amplification (RAA) assays incorporating
Document: BACKGROUND: Human adenoviruses are a common group of viruses that cause acute infectious diseases. Human adenovirus (HAdV) 3 and HAdV 7 cause major outbreaks of severe pneumonia. A reliable and practical method for HAdV typing in clinical laboratories is lacking. A simple, rapid and accurate molecular typing method for HAdV may facilitate clinical diagnosis and epidemiological control. METHODS: We developed and evaluated duplex real-time recombinase-aided amplification (RAA) assays incorporating competitive internal controls for detection of HAdV 3 and HAdV 7, respectively. The assays were performed in a one-step in a single tube reaction at 39° for 20 min. RESULTS: The analytical sensitivities of the duplex RAA assays for HAdV 3 and HAdV 7 were 5.0 and 14.8 copies per reaction, respectively (at 95% probability by probit regression analysis). No cross-reaction was observed with other types of HAdV or other common respiratory viruses. The duplex RAA assays were used to detect 152 previously-defined HAdV-positive samples. These results agreed with those obtained using a published triplex quantitative real-time PCR protocol. CONCLUSIONS: We provide the first report of internally-controlled duplex RAA assays for the detection of HAdV 3 and HAdV 7. These assays effectively reduce the rate of false negative results and may be valuable for detection of HAdV 3 and HAdV 7 in clinical laboratories, especially in resource-poor settings.
Search related documents:
Co phrase search for related documents- accurate rapid and acid amplification method: 1, 2, 3, 4, 5, 6, 7
- accurate rapid and acid extraction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- accurate rapid and acid sequence: 1, 2, 3
- accurate rapid and acute respiratory: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- accurate rapid and acute respiratory infection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- accurate rapid and adenoviridae family: 1
- accurate rapid and loop acid amplification method: 1, 2, 3, 4
- accurate rapid simple and acid amplification: 1, 2
- accurate rapid simple and acid sequence: 1
- accurate rapid simple and acute respiratory: 1, 2, 3, 4
- accurate rapid simple and acute respiratory infection: 1
- acid amplification and acute respiratory: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid amplification and acute respiratory infection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
- acid amplification and loop acid amplification method: 1, 2, 3, 4, 5, 6, 7, 8, 9
- acid amplification method and acute respiratory: 1, 2, 3, 4, 5, 6
- acid amplification method and loop acid amplification method: 1, 2, 3, 4, 5, 6, 7, 8, 9
- acid extraction and acute respiratory: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid extraction and acute respiratory infection: 1, 2, 3, 4, 5, 6
- acid sequence and acute respiratory: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
Co phrase search for related documents, hyperlinks ordered by date