Author: Bégin, André; Martel, Guillaume; Lapointe, Réal; Belblidia, Assia; Lepanto, Luigi; Soler, Luc; Mutter, Didier; Marescaux, Jacques; Vandenbroucke-Menu, Franck
Title: Accuracy of preoperative automatic measurement of the liver volume by CT-scan combined to a 3D virtual surgical planning software (3DVSP). Cord-id: 57i20o1m Document date: 2014_1_1
ID: 57i20o1m
Snippet: BACKGROUND Liver volumetry is a critical component of safe hepatic surgery, in order to minimize the risk of postoperative liver failure. Liver volumes can be calculated routinely using the time-consuming gold standard method of manual volumetry. The current work sought to evaluate an alternative automatic technique based on a novel 3D virtual planning software, and to compare it to the manual technique. METHODS A prospective study of patients undergoing liver resection was conducted. Every pati
Document: BACKGROUND Liver volumetry is a critical component of safe hepatic surgery, in order to minimize the risk of postoperative liver failure. Liver volumes can be calculated routinely using the time-consuming gold standard method of manual volumetry. The current work sought to evaluate an alternative automatic technique based on a novel 3D virtual planning software, and to compare it to the manual technique. METHODS A prospective study of patients undergoing liver resection was conducted. Every patient had a pre and 2-day postoperative CT-scan. For each patient, total, remnant and resected volumes were calculated manually and automatically. Planes of resection were verified by a hepatobiliary surgeon and compared with postoperative volumes. Paired t-tests and correlation coefficients were calculated. RESULTS A major hepatectomy was carried out in 36/43 patients. The automatic TLV (1,759 mL) and the manual TLV (1,832 mL) were significantly different (p < 0.001), but extremely highly correlated (r = 0.989). The percentages of preoperative RLV (manual 58.5%, automatic 58.9%) were similar, with an excellent correlation of 0.917. The preoperative RLV were matched with the 2-day postoperative RLV showing a significant difference (p = 0.0301). The resected volumes using both techniques (871 and 832 mL) were compared with the resected specimen volume (670 mL), showing a significant difference (p < 0.001) but a high degree of correlation (r = 0.874). CONCLUSION The 3D virtual surgical planning software is accurate and reliable in determining the total liver and future remnant liver volumes. This technique demonstrates a good correlation with the manual technique. Future work will be required to confirm these findings and to evaluate the clinical value of the three-dimensional planning platform.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date