Author: Rengasamy, Samy; Fisher, Edward; Shaffer, Ronald E.
Title: Evaluation of the survivability of MS2 viral aerosols deposited on filtering face piece respirator samples incorporating antimicrobial technologies Cord-id: bdnu8nhd Document date: 2009_11_5
ID: bdnu8nhd
Snippet: BACKGROUND: Respiratory protective devices exposed to pathogenic microorganisms present a potential source of transmission of infection during handling. In this study, the efficacy of 4 antimicrobial respirators to decontaminate MS2, a surrogate for pathogenic viruses, was evaluated and compared with control N95 filtering face piece respirators, which did not contain any known antimicrobial components. METHODS: MS2 containing droplet nuclei were generated using a Collison nebulizer and loaded on
Document: BACKGROUND: Respiratory protective devices exposed to pathogenic microorganisms present a potential source of transmission of infection during handling. In this study, the efficacy of 4 antimicrobial respirators to decontaminate MS2, a surrogate for pathogenic viruses, was evaluated and compared with control N95 filtering face piece respirators, which did not contain any known antimicrobial components. METHODS: MS2 containing droplet nuclei were generated using a Collison nebulizer and loaded onto respirator coupons at a face velocity of 13.2 cm/seconds for 30 minutes. The coupons were incubated at 2 different temperature and relative humidity (RH) conditions and analyzed for viable MS2 at different time intervals. RESULTS: Results showed that log(10) reduction of MS2 was not statistically significant (P > .05) between the control and antimicrobial respirator coupons, when stored at 22°C and 30% RH up to 20 hours. Coupons from 1 of the 4 antimicrobial respirators showed an average MS2 log(10) reduction of 3.7 at 37°C and 80% RH for 4 hours, which was statistically significant (P ≤ .05) compared with coupons from the control respirators. CONCLUSION: Results from this study suggest that MS2 virus decontamination efficacy of antimicrobial respirators is dependent on the antimicrobial agent and storage conditions.
Search related documents:
Co phrase search for related documents- acute respiratory syndrome and log 10 reduction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- acute respiratory syndrome and log reduction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory syndrome and long survive: 1, 2, 3, 4