Selected article for: "Ã pixel size and electron microscope"

Author: Chuang Liu; Yang Yang; Yuanzhu Gao; Chenguang Shen; Bin Ju; Congcong Liu; Xian Tang; Jinli Wei; Xiaomin Ma; Weilong Liu; Shuman Xu; Yingxia Liu; Jing Yuan; Jing Wu; Zheng Liu; Zheng Zhang; Peiyi Wang; Lei Liu
Title: Viral Architecture of SARS-CoV-2 with Post-Fusion Spike Revealed by Cryo-EM
  • Document date: 2020_3_5
  • ID: cr22vp8b_32
    Snippet: Frozen grid was transferred to a Titan Krios transmission electron microscope (Thermo Fisher Scientific) performed at the 300 kV and images were recorded by a Falcon III direct electron detector (Thermo Fisher Scientific). Image stacks with 16 frames were collected in linear mode by EPU at a nominal magnification of 59000 x, corresponding to a pixel size of 1.14 Ã…/pixel. Total dose was estimated at about 60 e -/Ã… 2 . Length, the diameter of ste.....
    Document: Frozen grid was transferred to a Titan Krios transmission electron microscope (Thermo Fisher Scientific) performed at the 300 kV and images were recorded by a Falcon III direct electron detector (Thermo Fisher Scientific). Image stacks with 16 frames were collected in linear mode by EPU at a nominal magnification of 59000 x, corresponding to a pixel size of 1.14 Ã…/pixel. Total dose was estimated at about 60 e -/Ã… 2 . Length, the diameter of stem and spike's head are 23nm, 4nm and 7nm, respectively.

    Search related documents:
    Co phrase search for related documents
    • direct electron and nominal magnification: 1
    • direct electron and pixel size: 1, 2, 3
    • direct electron and Thermo Fisher Scientific direct electron detector: 1
    • direct electron and total dose: 1, 2
    • direct electron and transmission electron: 1, 2, 3, 4
    • direct electron and transmission electron microscope: 1
    • direct electron detector and image stack: 1
    • direct electron detector and nominal magnification: 1
    • direct electron detector and pixel size: 1, 2, 3
    • direct electron detector and Thermo Fisher Scientific direct electron detector: 1
    • direct electron detector and total dose: 1, 2
    • image stack and nominal magnification: 1
    • image stack and pixel size: 1
    • image stack and total dose: 1
    • nominal magnification and pixel size: 1, 2, 3
    • nominal magnification and Thermo Fisher Scientific transmission electron microscope: 1
    • nominal magnification and total dose: 1
    • nominal magnification and transmission electron: 1, 2
    • nominal magnification and transmission electron microscope: 1, 2