Author: Micha Sam Brickman Raredon; Clark Fisher; Paul Heerdt; Ranjit Deshpande; Steven Nivison; Elaine Fajardo; Shamsuddin Akhtar; Thomas Raredon; Laura E. Niklason
Title: Pressure-Regulated Ventilator Splitting (PReVentS): A COVID-19 Response Paradigm from Yale University Document date: 2020_4_6
ID: mqj071gp_65
Snippet: To document proof-of-principle for the PReVentS circuit, and to test its ability to separately control ventilatory pressures for two patients, we assembled the circuit attached to a standard ICU ventilator. Standard test lungs (eg. BioMed Device # 1020 or similar) were used to simulate patient lungs. To simulate a decrease in lung compliance, we applied rubber bands around one of the test lungs to increase their stiffness. Figures 10-14 below sho.....
Document: To document proof-of-principle for the PReVentS circuit, and to test its ability to separately control ventilatory pressures for two patients, we assembled the circuit attached to a standard ICU ventilator. Standard test lungs (eg. BioMed Device # 1020 or similar) were used to simulate patient lungs. To simulate a decrease in lung compliance, we applied rubber bands around one of the test lungs to increase their stiffness. Figures 10-14 below show data obtained from the PReVentS circuit as described above. With the current hand-made valves it is necessary to briefly open the circuit to make valve adjustments. We are working to update the valve design so that pressures can be set without making any disconnects in the PReVentS circuit.
Search related documents:
Co phrase search for related documents- briefly circuit open and PReVentS circuit: 1
- circuit open and lung compliance: 1
- circuit open and patient lung: 1, 2
- circuit open and PReVentS circuit: 1
- ICU ventilator and lung compliance: 1, 2, 3, 4, 5
- ICU ventilator and patient lung: 1, 2
- lung compliance and patient lung: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- lung compliance and PReVentS circuit: 1, 2, 3
- patient lung and PReVentS circuit: 1, 2, 3
- patient lung simulate and PReVentS circuit: 1
Co phrase search for related documents, hyperlinks ordered by date