Author: Ben Abdelhanin, Myriam; Mvumbi, Dieudonné M; Agathine, Aurélie; Nanos, Nikolaos; Gidenne, Stéphane
Title: Evaluation of the Elecsys SARS-CoV-2 antigen assay for the detection of SARS-CoV-2 in nasopharyngeal swabs. Cord-id: cav0nvtb Document date: 2021_10_1
ID: cav0nvtb
Snippet: AIMS: The aim of this study was to evaluate the performance of the automated Elecsys® SARS-CoV-2 antigen assay compared to RT-PCR taken as the gold standard for SARS-CoV-2 detection. METHODS: 225 nasopharyngeal swabs were randomly collected among which 123 were tested positive and 102 negatives for SARS-CoV-2 based on RT-PCR. Antigen dosing were performed on a Cobas 8000 e801 analyzer. RESULTS: The antigen test diagnosed SARS-CoV-2 infection status with an overall sensitivity of 65,85% (95% CI
Document: AIMS: The aim of this study was to evaluate the performance of the automated Elecsys® SARS-CoV-2 antigen assay compared to RT-PCR taken as the gold standard for SARS-CoV-2 detection. METHODS: 225 nasopharyngeal swabs were randomly collected among which 123 were tested positive and 102 negatives for SARS-CoV-2 based on RT-PCR. Antigen dosing were performed on a Cobas 8000 e801 analyzer. RESULTS: The antigen test diagnosed SARS-CoV-2 infection status with an overall sensitivity of 65,85% (95% CI 56,76–74,16%), a specificity of 100% (95% CI 96,49–100%) with a Cut-off value ≥ 1. When the cut-off value for the antigen assay was set to > 0,673 COI, the accuracy reached its highest level with a sensitivity of 74,8% (95% CI 66,2 – 82,2%) and a specificity of 97,1% (95% CI 91,6 – 99,4%). Imprecision was estimated in accordance with manufacturer's claims. CONCLUSIONS: We obtained an overall sensitivity of 65,85% (95% CI 56,76–74,16%) and a specificity of 100% (95% CI 96,49–100%), slightly higher than the results reported by the manufacturer. Yet, it remains relatively low comparatively to what is generally acceptable for these antigenic assays (a relative sensitivity of 80%). We also noticed that the accuracy could reach its highest level if the cut-off is set above 0,673 which is lower than established by the manufacturer. Thus, our results suggest that the Elecsys® SARS-CoV-2 Antigen assays, should be improved prior to be used in a SARS-Cov-2 screening strategy. However, if one antigenic assay could demonstrate acceptable performance, it might be centralized in clinical laboratories, keeping the RT-PCR in a second phase for confirmation.
Search related documents:
Co phrase search for related documents- acceptable sensitivity and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6
- acceptable sensitivity and low sensitivity: 1, 2, 3, 4
- acid extraction and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid extraction and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid extraction and low sensitivity: 1
- acute respiratory syndrome and low sensibility: 1, 2
- acute respiratory syndrome and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
Co phrase search for related documents, hyperlinks ordered by date