Author: Lucia Grenga; Fabrice Gallais; Olivier Pible; Jean-Charles Gaillard; Duarte Gouveia; Hélène Batina; Niza Bazaline; Sylvie Ruat; Karen Culotta; Guylaine Miotello; Stéphanie Debroas; Marie-Anne Roncato; Gérard Steinmetz; Charlotte Foissard; Anne Desplan; Béatrice Alpha-Bazin; Christine Almunia; Fabienne Gas; Laurent Bellanger; Jean Armengaud
Title: Shotgun proteomics of SARS-CoV-2 infected cells and its application to the optimisation of whole viral particle antigen production for vaccines Document date: 2020_4_17
ID: kd02dehk_12
Snippet: Peptides were identified using an ultimate 3000 nano-LC system (Thermo Fisher Scientific) coupled with a Q-Exactive HF mass spectrometer (Thermo Fisher Scientific). Peptides were desalted on a reversed-phase PepMap 100 C18 μ-precolumn (5 μm, 100 Å, 300 μm i.d. × 5 mm, Thermo Fisher Scientific) before peptide separation on a nanoscale PepMap 100 C18 nanoLC column (3 μm, 100 Å, 75 μm i.d. × 50 cm, Thermo Fisher Scientific) at a flow rate o.....
Document: Peptides were identified using an ultimate 3000 nano-LC system (Thermo Fisher Scientific) coupled with a Q-Exactive HF mass spectrometer (Thermo Fisher Scientific). Peptides were desalted on a reversed-phase PepMap 100 C18 μ-precolumn (5 μm, 100 Å, 300 μm i.d. × 5 mm, Thermo Fisher Scientific) before peptide separation on a nanoscale PepMap 100 C18 nanoLC column (3 μm, 100 Å, 75 μm i.d. × 50 cm, Thermo Fisher Scientific) at a flow rate of 0.2 μL per min using a 120 min gradient comprising 100 min from 4% to 25% of solvent B and 20 min from 25% to 40% of solvent B (solvent A consisted in 0.1% formic acid in water, solvent B was 80% acetonitrile, 0.1% formic acid in water). The mass spectrometer was operated in Top20 mode. Full MS were acquired from 350 to 1,500 m/z and the 20 most abundant precursor ions were selected for fragmentation with 10 s dynamic exclusion time. Ions with 2+ and 3+ charge were selected for MS/MS analysis. Secondary ions were isolated with a window of 2.0 m/z. author/funder. All rights reserved. No reuse allowed without permission.
Search related documents:
Co phrase search for related documents- dynamic exclusion and formic acid: 1, 2, 3
- dynamic exclusion and mass spectrometer: 1, 2
- dynamic exclusion and MS MS analysis: 1
- dynamic exclusion and precursor ion: 1, 2
- flow rate and formic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
- flow rate and HF mass spectrometer: 1
- flow rate and μl flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- flow rate and mass spectrometer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- flow rate and MS MS analysis: 1, 2
- flow rate and nano LC system: 1
- flow rate and precursor ion: 1, 2
- formic acid and HF mass spectrometer: 1, 2
- formic acid and μl flow rate: 1, 2, 3, 4
- formic acid and mass spectrometer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- formic acid and MS MS analysis: 1, 2, 3, 4
- formic acid and nano LC system: 1
- formic acid and precursor ion: 1
- HF mass spectrometer and mass spectrometer: 1, 2
- μl flow rate and mass spectrometer: 1, 2
Co phrase search for related documents, hyperlinks ordered by date