Author: Schlaudecker, Elizabeth P.; Heck, Joan P.; MacIntyre, Elizabeth T.; Martinez, Ruben; Dodd, Caitlin N.; McNeal, Monica M.; Staat, Mary A.; Heck, Jeffery E.; Steinhoff, Mark C.
Title: Comparison of a new transport medium with universal transport medium at a tropical field site Cord-id: 4aj2t80s Document date: 2014_10_31
ID: 4aj2t80s
Snippet: Abstract Limited data are available in rural Honduran settings describing the etiology of respiratory infections, partially due to limited specimen transport. A new molecular transport media (MTM) preserves released nucleic acid at ambient temperature for later detection. Prospective surveillance was conducted in a Honduran clinic to identify 233 children less than 5 years of age presenting with respiratory symptoms. We obtained 2 nasopharyngeal samples and stored 1 in PrimeStore® MTM at room t
Document: Abstract Limited data are available in rural Honduran settings describing the etiology of respiratory infections, partially due to limited specimen transport. A new molecular transport media (MTM) preserves released nucleic acid at ambient temperature for later detection. Prospective surveillance was conducted in a Honduran clinic to identify 233 children less than 5 years of age presenting with respiratory symptoms. We obtained 2 nasopharyngeal samples and stored 1 in PrimeStore® MTM at room temperature and 1 in universal transport media (UTM) at −80 °C. The specimens were then transported to Cincinnati Children's Hospital and tested for 16 respiratory viruses using a multiplex PCR panel. The 2 specimen collection systems were similar for detecting the 4 most common viruses: influenza (Kappa = 0.7676, P < 0.0001), human metapneumovirus (Kappa = 0.8770, P < 0.0001), respiratory syncytial virus (Kappa = 0.6849, P < 0.0001), and parainfluenza (Kappa = 0.8796, P < 0.0001). These results suggest that clinical specimens transported via PrimeStore® MTM and UTM yield similar viral multiplex PCR results.
Search related documents:
Co phrase search for related documents- acid amplification test and low sensitivity: 1
- acid detection and acute respiratory infection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
- acid detection and low number: 1
- acid detection and low resource: 1, 2, 3, 4, 5
- acid detection and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14
- acid detection and luminex diagnostics: 1, 2
- acute respiratory infection and low number: 1, 2, 3, 4, 5, 6, 7, 8
- acute respiratory infection and low resource: 1, 2
- acute respiratory infection and low sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- low sensitivity and luminex diagnostics: 1
Co phrase search for related documents, hyperlinks ordered by date