Author: Gandotra, N.; Tikhonova, I.; Cheermarla, N. R.; Knight, J.; Foxman, E.; Giraldez, A.; Shen, P.; Bilguvar, K.; Scharfe, C.
Title: A two-pronged approach for rapid and high-throughput SARS-CoV-2 nucleic acid testing Cord-id: 5ek0km9l Document date: 2020_12_7
ID: 5ek0km9l
Snippet: Improved molecular screening and diagnostic tools are needed to substantially increase SARS-CoV-2 testing capacity and throughput while reducing the time to receive test results. Here we developed multiplex reverse transcriptase polymerase chain reaction (m-RT-PCR) for detection of SARS-CoV-2 using rapid DNA electrophoresis and alternatively using multiplex viral sequencing (mVseq). For RNA specimens extracted from nasopharyngeal (NP) swabs in viral transport media (VTM), our assays achieved a s
Document: Improved molecular screening and diagnostic tools are needed to substantially increase SARS-CoV-2 testing capacity and throughput while reducing the time to receive test results. Here we developed multiplex reverse transcriptase polymerase chain reaction (m-RT-PCR) for detection of SARS-CoV-2 using rapid DNA electrophoresis and alternatively using multiplex viral sequencing (mVseq). For RNA specimens extracted from nasopharyngeal (NP) swabs in viral transport media (VTM), our assays achieved a sensitivity for SARS-CoV-2 detection corresponding to cycle threshold (Ct) of 37.2 based on testing of these specimens using quantitative reverse transcription PCR (RT-qPCR). For NP swab-VTM specimens without prior RNA extraction, sensitivity was reduced to Ct of 31.6, which was due to lower concentration of SARS-CoV-2 genome copies in VTM compared to RNA-extracted samples. Assay turnaround time was 60 minutes using rapid gel electrophoresis, 90 minutes using Agilent Bioanalyzer, and 24-48 hours using Illumina sequencing, the latter of which required a second PCR to produce a sequence-ready library using m-RT-PCR products as the template. Our assays can be employed for high-throughput sequencing-based detection of SARS-CoV-2 directly from a clinical specimen without RNA isolation, while ease-of-use and low cost of the electrophoresis-based readout enables screening, particularly in resource-constrained settings.
Search related documents:
Co phrase search for related documents- additional evaluation and load sample: 1
- additional evaluation and low viral load sample: 1
- load sample and low viral load sample: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
Co phrase search for related documents, hyperlinks ordered by date