Author: Liu, Xinjin; Feng, Jiangpeng; Zhang, Qiuhan; Guo, Dong; Zhang, Lu; Suo, Tao; Hu, Wenjia; Guo, Ming; Wang, Xin; Huang, Zhixiang; Xiong, Yong; Chen, Guozhong; Chen, Yu; Lan, Ke
Title: Analytical comparisons of SARS-COV-2 detection by qRT-PCR and ddPCR with multiple primer/probe sets Cord-id: 4joyw8zs Document date: 2020_6_4
ID: 4joyw8zs
Snippet: Different primers/probes sets have been developed all over the world for the nucleic acid detection of SARS-CoV-2 by quantitative real time polymerase chain reaction (qRT-PCR) as a standard method. In our recent study, we explored the feasibility of droplet digital PCR (ddPCR) for clinical SARS-CoV-2 nucleic acid detection compared with qRT-PCR using the same primer/probe sets issued by Chinese Center for Disease Control and Prevention (CDC) targeting viral ORF1ab or N gene, which showed that dd
Document: Different primers/probes sets have been developed all over the world for the nucleic acid detection of SARS-CoV-2 by quantitative real time polymerase chain reaction (qRT-PCR) as a standard method. In our recent study, we explored the feasibility of droplet digital PCR (ddPCR) for clinical SARS-CoV-2 nucleic acid detection compared with qRT-PCR using the same primer/probe sets issued by Chinese Center for Disease Control and Prevention (CDC) targeting viral ORF1ab or N gene, which showed that ddPCR could largely minimize the false negatives reports resulted by qRT-PCR [Suo T, Liu X, Feng J, et al. ddPCR: a more sensitive and accurate tool for SARS-CoV-2 detection in low viral load specimens. medRxiv [Internet]. 2020;2020.02.29.20029439. Available from: https://medrxiv.org/content/early/2020/03/06/2020.02.29.20029439.abstract]. Here, we further stringently compared the performance of qRT-PCR and ddPCR for 8 primer/probe sets with the same clinical samples and conditions. Results showed that none of 8 primer/probe sets used in qRT-PCR could significantly distinguish true negatives and positives with low viral load (10(−4) dilution). Moreover, false positive reports of qRT-PCR with UCDC-N1, N2 and CCDC-N primers/probes sets were observed. In contrast, ddPCR showed significantly better performance in general for low viral load samples compared to qRT-PCR. Remarkably, the background readouts of ddPCR are relatively lower, which could efficiently reduce the production of false positive reports.
Search related documents:
Co phrase search for related documents- acid detection and acute respiratory syndrome coronavirus: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acid detection and load sample: 1
- acid detection and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- acid detection and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
- acid detection and low viral load sample: 1
- acute respiratory syndrome coronavirus and load sample: 1, 2, 3, 4, 5
- acute respiratory syndrome coronavirus and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory syndrome coronavirus and lod detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- acute respiratory syndrome coronavirus and low consistency: 1
- acute respiratory syndrome coronavirus and low percentage: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
- acute respiratory syndrome coronavirus and low virus concentration: 1, 2, 3, 4
- load sample and low viral load sample: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- load sample and low viral load sample detection: 1, 2
- lod detection and low virus concentration: 1, 2
- lod detection limit and low virus concentration: 1, 2
Co phrase search for related documents, hyperlinks ordered by date