Author: Kim, Sang-Hyun; Lilot, Marc; Sidhu, Kulraj S; Rinehart, Joseph; Yu, Zhaoxia; Canales, Cecilia; Cannesson, Maxime
Title: Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Cord-id: bm02knub Document date: 2014_1_1
ID: bm02knub
Snippet: BACKGROUND Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. METHODS The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressu
Document: BACKGROUND Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. METHODS The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressure, and mean arterial pressure were calculated. Continuous noninvasive arterial pressure monitoring was considered acceptable if pooled estimates of bias and SD were not greater than 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation. RESULTS Twenty-eight studies (919 patients) were included. The overall random-effect pooled bias and SD were -1.6 ± 12.2 mmHg (95% limits of agreement -25.5 to 22.2 mmHg) for systolic arterial pressure, 5.3 ± 8.3 mmHg (-11.0 to 21.6 mmHg) for diastolic arterial pressure, and 3.2 ± 8.4 mmHg (-13.4 to 19.7 mmHg) for mean arterial pressure. In 14 studies focusing on currently commercially available devices, bias and SD were -1.8 ± 12.4 mmHg (-26.2 to 22.5 mmHg) for systolic arterial pressure, 6.0 ± 8.6 mmHg (-10.9 to 22.9 mmHg) for diastolic arterial pressure, and 3.9 ± 8.7 mmHg (-13.1 to 21.0 mmHg) for mean arterial pressure. CONCLUSIONS The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable. This may have implications for clinical situations where continuous noninvasive arterial pressure is being used for patient care decisions.
Search related documents:
Co phrase search for related documents- Try single phrases listed below for: 1
Co phrase search for related documents, hyperlinks ordered by date