Author: Porada, Radosław; Fendrych, Katarzyna; Baś, Bogusław
Title: Electrochemical sensor based on Ni-exchanged natural zeolite/carbon black hybrid nanocomposite for determination of vitamin B(6) Cord-id: 5s4u8ad0 Document date: 2021_9_6
ID: 5s4u8ad0
Snippet: The utilization of environmentally friendly nanoporous natural zeolite exchanged with Ni(2+) ions (NiZ) and conductive carbon black (CB) in the fabrication of a novel and selective voltammetric sensor of vitamin B(6) (VB(6)) is presented. The used clinoptilolite-rich zeolite material and CB were characterized in terms of morphology and textural properties. The superior properties of Ni-zeolite/carbon black modified glassy carbon electrode (NiZCB-GCE), arising from the synergistic effect of combi
Document: The utilization of environmentally friendly nanoporous natural zeolite exchanged with Ni(2+) ions (NiZ) and conductive carbon black (CB) in the fabrication of a novel and selective voltammetric sensor of vitamin B(6) (VB(6)) is presented. The used clinoptilolite-rich zeolite material and CB were characterized in terms of morphology and textural properties. The superior properties of Ni-zeolite/carbon black modified glassy carbon electrode (NiZCB-GCE), arising from the synergistic effect of combining the unique features of zeolite and conductive carbon black, were confirmed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements. In the determination of VB(6) with the use of differential pulse voltammetry (DPV), the optimization of the pH value of supporting electrolyte and instrumental parameters, as well as the interference study were performed. Under optimized conditions, the oxidation peak current at the potential +0.72 V vs. Ag | AgCl | 3 M KCl reference electrode was linear to the VB(6) concentration in the range 0.050 to 1.0 mg L(−1) (0.30–5.9 μmol L(−1)) (R = 0.9993). The calculated limit of detection (LOD, S/N = 3), equal to 15 μg L(−1) (0.09 μmol L(−1)), was much better compared to chemically modified electrodes with other carbon-based materials. The RSD for 0.5 mg L(−1) was in the range 2.5–5.4% (n = 4). The developed NiZCB-GCE was successfully applied to the determination of VB(6) in commercially available multivitamin dietary supplements, food, and water samples. The obtained recoveries ranged from 95 to 106%. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-021-04992-x.
Search related documents:
Co phrase search for related documents- accurate simple and lod detection limit: 1, 2, 3, 4
- addition method and lod detection limit: 1, 2, 3, 4, 5, 6, 7
Co phrase search for related documents, hyperlinks ordered by date