Author: Bwire, George M.; Majigo, Mtebe V.; Njiro, Belinda J.; Mawazo, Akili
Title: Detection profile of SARSâ€CoVâ€2 using RTâ€PCR in different types of clinical specimens: A systematic review and metaâ€analysis Cord-id: ee71hggp Document date: 2020_8_2
ID: ee71hggp
Snippet: Testing is one of the commendable measures for curbing the spread of coronavirus disease (COVIDâ€19). But, it should be done using the most appropriate specimen and an accurate diagnostic test such as realâ€time reverse transcriptionâ€polymerase chain reaction (qRTâ€PCR). Therefore, a systematic review was conducted to determine the positive detection rate of severe acute respiratory syndrome coronavirus 2 (SARSâ€CoVâ€2) in different clinical specimens using qRTâ€PCR. A total of 8136 pool
Document: Testing is one of the commendable measures for curbing the spread of coronavirus disease (COVIDâ€19). But, it should be done using the most appropriate specimen and an accurate diagnostic test such as realâ€time reverse transcriptionâ€polymerase chain reaction (qRTâ€PCR). Therefore, a systematic review was conducted to determine the positive detection rate of severe acute respiratory syndrome coronavirus 2 (SARSâ€CoVâ€2) in different clinical specimens using qRTâ€PCR. A total of 8136 pooled clinical specimens were analyzed to detect SARSâ€CoVâ€2, the majority were nasopharyngeal swabs (69.6%). A lower respiratory tract (LRT) specimens had a positive rate (PR) of 71.3% (95% confidence interval [CI]: 60.3%â€82.3%) while no virus was detected in the urinogenital specimens. Bronchoalveolar lavage fluid (BLF) specimen had the PR of 91.8% (95% CI: 79.9%â€103.7%), followed by rectal swabs; 87.8% (95% CI: 78.6%â€96.9%) then sputum; 68.1% (95% CI: 56.9%â€79.4%). A low PR was observed in oropharyngeal swabs; 7.6% (95% CI: 5.7%â€9.6%) and blood samples; 1.0% (95% CI: −0.1%â€2.1%) whereas no SARSâ€CoVâ€2 was detected in urine samples. Feces had a PR of 32.8% (95% CI:1 5.8%â€49.8%). Nasopharyngeal swab, a widely used specimen had a PR of 45.5% (95% CI: 31.2%â€59.7%). In this study, SARSâ€CoVâ€2 was highly detected in LRT specimens while no virus was detected in urinogenital specimens. BLF had the highest PR followed by rectal swab then sputum. Nasopharyngeal swab which is widely used had moderate PR. Low PR was recorded in oropharyngeal swab and blood samples while no virus was found in urine samples. Last, the virus was detected in feces, suggesting SARSâ€CoVâ€2 transmission by the fecal route.
Search related documents:
Co phrase search for related documents- additional file and low respiratory tract: 1
- low detection rate and lrt specimen: 1
Co phrase search for related documents, hyperlinks ordered by date