Selected article for: "absence presence and adhesion frequency"

Author: Kanai, Eiichi; Matsutani, Noriyuki; Aso, Tatsuya; Yamamoto, Yasuto; Sakai, Takashi
Title: Long-term effects of pleural defect repair using sheet materials in a canine model.
  • Cord-id: cceev3o5
  • Document date: 2019_12_11
  • ID: cceev3o5
    Snippet: OBJECTIVE A sheet material is widely used to repair pleural defects due to its excellent pressure resistance. We examined the long-term effects of sheet materials using an animal pleural defect model. METHODS Beagles were used for this study. The 5-mm circular pleural defects were created at 2 sites on each of the anterior, medial, and posterior lobe and repaired using a 2 cm square sheet material. The frequency of adhesion of those sheets to the thoracic walls and histological changes was exami
    Document: OBJECTIVE A sheet material is widely used to repair pleural defects due to its excellent pressure resistance. We examined the long-term effects of sheet materials using an animal pleural defect model. METHODS Beagles were used for this study. The 5-mm circular pleural defects were created at 2 sites on each of the anterior, medial, and posterior lobe and repaired using a 2 cm square sheet material. The frequency of adhesion of those sheets to the thoracic walls and histological changes was examined after 6 months. In this study, three types of sheet materials were examined: polyglycolic acid, nano-polyglycolic acid, and oxidized regenerated cellulose where each sheet was tested with or without coating with fibrin glue, for a total of 6 groups. Each group contained an equal number of defect sites and evaluation of 12 defect sites was conducted. RESULTS Adhesion was observed in 16 of 72 sites (22%). Presence or absence of adhesion was not affected by the repair method or by the type of sheet material used. However, the use of fibrin glue significantly reduced the occurrence of adhesion (p = 0.023). At the defected sites, the posterior lobe showed significantly less adhesion (p = 0.019). Histologically, the sheet materials caused a thickening of the pleural wall 6-10 times thicker than the normal pleural wall. CONCLUSION No statistically significant differences regarding the presence or absence of adhesion to the thoracic wall were found among the sheet materials. The use of fibrin glue significantly reduced the adhesion to the thoracic wall.

    Search related documents:
    Co phrase search for related documents
    • absence presence and adhesion absence presence: 1, 2, 3
    Co phrase search for related documents, hyperlinks ordered by date