Selected article for: "detection limit and good reproducibility"

Author: Zhang, Kai; Fan, Zhenqiang; Ding, Yuedi; Xie, Minhao
Title: A pH-engineering regenerative DNA tetrahedron ECL biosensor for the assay of SARS-CoV-2 RdRp gene based on CRISPR/Cas12a trans-activity
  • Cord-id: 75txy5e5
  • Document date: 2022_2_1
  • ID: 75txy5e5
    Snippet: In this work, we constructed an exonuclease III cleavage reaction-based isothermal amplification of nucleic acids with CRISPR/Cas12a-mediated pH-induced regenerative Electrochemiluminescence (ECL) biosensor for ultrasensitive and specific detection of SARS-CoV-2 nucleic acids for SARS-CoV-2 diagnosis. The triple-stranded nucleic acid in this biosensor has an extreme dependence on pH, which makes our constructed biosensor reproducible. This is essential for effective large-scale screening of SARS
    Document: In this work, we constructed an exonuclease III cleavage reaction-based isothermal amplification of nucleic acids with CRISPR/Cas12a-mediated pH-induced regenerative Electrochemiluminescence (ECL) biosensor for ultrasensitive and specific detection of SARS-CoV-2 nucleic acids for SARS-CoV-2 diagnosis. The triple-stranded nucleic acid in this biosensor has an extreme dependence on pH, which makes our constructed biosensor reproducible. This is essential for effective large-scale screening of SARS-CoV-2 in areas where resources are currently relatively scarce. Using this pH-induced regenerative biosensor, we detected the SARS-CoV-2 RdRp gene with a detection limit of 43.70 aM. In addition, the detection system has good stability and reproducibility, and we expect that this method may provide a potential platform for the diagnosis of COVID-19.

    Search related documents:
    Co phrase search for related documents
    • accuracy high specificity and acid sequence: 1
    • accuracy high specificity and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • accuracy specificity and acid amplification: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
    • accuracy specificity and acid probe: 1
    • accuracy specificity and acid sequence: 1, 2, 3, 4
    • accuracy specificity and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • accurate monitoring and acid amplification: 1
    • accurate monitoring and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • accurate powerful and acid sequence: 1
    • accurate powerful and acute respiratory syndrome: 1, 2
    • acid amplification and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • acid amplification enzyme and acute respiratory syndrome: 1, 2, 3
    • acid amplification reaction and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • acid cleavage and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
    • acid dissociation and acute respiratory syndrome: 1
    • acid fragment and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • acid marker and acute respiratory syndrome: 1, 2
    • acid probe and acute respiratory syndrome: 1, 2, 3, 4, 5
    • acid sequence and acute respiratory syndrome: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25