Selected article for: "biosensor system and care point"

Author: Xu, Wenjuan; Liu, Jiayao; Song, Dan; Li, Chunsheng; Zhu, Anna; Long, Feng
Title: Rapid, label-free, and sensitive point-of-care testing of anti-SARS-CoV-2 IgM/IgG using all-fiber Fresnel reflection microfluidic biosensor
  • Cord-id: 7b9mp8tn
  • Document date: 2021_7_19
  • ID: 7b9mp8tn
    Snippet: The ongoing global pandemic of SARS-CoV-2 has promoted to develop novel serological testing technologies since they can be effectively complementary to RT-PCR. Here, a new all-fiber Fresnel reflection microfluidic biosensor (FRMB) was constructed through combining all-fiber optical system, microfluidic chip, and multimode fiber bio-probe. The transmission of the incident light and the collection and transmission of Fresnel reflection light are achieved using a single-multi-mode fiber optic coupl
    Document: The ongoing global pandemic of SARS-CoV-2 has promoted to develop novel serological testing technologies since they can be effectively complementary to RT-PCR. Here, a new all-fiber Fresnel reflection microfluidic biosensor (FRMB) was constructed through combining all-fiber optical system, microfluidic chip, and multimode fiber bio-probe. The transmission of the incident light and the collection and transmission of Fresnel reflection light are achieved using a single-multi-mode fiber optic coupler (SMFC) without any other optical separation elements. This compact design greatly simplifies the whole system structure and improves light transmission efficiency, which makes it suitable for the label-free, sensitive, and easy-to-use point-of-care testing (POCT) of targets in nanoliter samples. Based on Fresnel reflection mechanism and immunoassay principle, both the SARS-CoV-2 IgM and IgG antibodies against the SARS-CoV-2 spike protein could be sensitively quantified in 7 min using the secondary antibodies-modified multimode fiber bio-probe. The FRMB performs in one-step, is accurate, label-free, and sensitive in situ/on-site detection of SARS-CoV-2 IgM or IgG in serum with simple dilution only. The limits of detection of SARS-CoV-2 IgM and SARS-CoV-2 IgG were 0.82 ng/mL and 0.45 ng/mL, respectively. Based on our proposed theory, the affinity constants of SARS-CoV-2 IgM or IgG antibody and their respective secondary antibodies were also determined. The FRMB can be readily extended as a universal platform for the label-free, rapid, and sensitive in situ/on-site measurement of other biomarkers and the investigation of biomolecular interaction. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-021-04911-0.

    Search related documents:
    Co phrase search for related documents
    • accurate rapid and lod detection: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
    • accurate rapid and long turnaround time: 1, 2, 3, 4
    • accurate rapid and low concentration: 1, 2, 3, 4, 5, 6, 7
    • accurate rapid detection and acid real time polymerase chain reaction: 1
    • accurate rapid detection and lod detection: 1, 2, 3, 4, 5
    • accurate rapid detection and long turnaround time: 1, 2
    • accurate rapid detection and low concentration: 1, 2, 3, 4
    • accurate timely and acid real time polymerase chain reaction: 1
    • accurate timely and low concentration: 1
    • acid real time polymerase chain reaction and lod detection: 1, 2
    • actual lod and lod detection: 1, 2
    • additional method and lod detection: 1
    • local refractive index and lod detection: 1
    • lod detection and long turnaround time: 1
    • lod detection and low concentration: 1, 2, 3, 4, 5, 6