Selected article for: "column purification and lysis buffer"

Author: Monica Sentmanat; Evguenia Kouranova; Xiaoxia Cui
Title: One-step RNA extraction for RT-qPCR detection of 2019-nCoV
  • Document date: 2020_4_5
  • ID: ihhu7nef_7
    Snippet: We presented here an improvement to the standard 2019-nCoV RT-qPCR test. We modified the RNA extraction step by using a one-step lysis buffer, bypassing the use of column purification. Our indicators for adequate assay performance are consistent with CDC assay interpretation guidelines, the detection of a Ct level of <40 for 2019-nCoV positive control counterparts and for RNaseP reference signal for positive controls and experimental samples 4 . .....
    Document: We presented here an improvement to the standard 2019-nCoV RT-qPCR test. We modified the RNA extraction step by using a one-step lysis buffer, bypassing the use of column purification. Our indicators for adequate assay performance are consistent with CDC assay interpretation guidelines, the detection of a Ct level of <40 for 2019-nCoV positive control counterparts and for RNaseP reference signal for positive controls and experimental samples 4 . The direct lysis takes less than 20 min to process samples ready for RT-qPCR and can be easily scaled up to a 96-well format and obtain higher throughput. The cost of the lysis buffer is much lower than that of a column purification kit. The lysis only requires a regular PCR machine and does not need a centrifuge or a manifold, as column purification requires.

    Search related documents:
    Co phrase search for related documents
    • assay performance and experimental sample: 1, 2, 3, 4
    • assay performance and extraction step: 1
    • assay performance and high throughput: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53
    • assay performance and lysis buffer: 1, 2
    • assay performance and positive control: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • assay performance and purification kit: 1
    • assay performance and RT qpcr: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29
    • assay performance and RT qpcr test: 1
    • assay performance and standard RT qpcr test: 1
    • column purification and control counterpart: 1
    • column purification and direct lysis: 1
    • column purification and experimental sample: 1
    • column purification and extraction step: 1
    • column purification and high throughput: 1
    • column purification and lysis buffer: 1, 2, 3
    • column purification and positive control: 1
    • column purification and positive control counterpart: 1
    • column purification and purification kit: 1, 2, 3
    • column purification and RNA extraction step: 1