Selected article for: "detection limit and gene detection limit"

Author: Gwon, Yong-Dae; Strand, Mårten; Lindqvist, Richard; Nilsson, Emma; Saleeb, Michael; Elofsson, Mikael; Överby, Anna K.; Evander, Magnus
Title: Antiviral Activity of Benzavir-2 against Emerging Flaviviruses
  • Document date: 2020_3_22
  • ID: 0ym40eki_24
    Snippet: To generate the ZIKV NS5 gene standard curve, a 105 bp ZIKV NS5 PCR amplicon was cloned into a pJET1.2 vector (Thermo Fisher, Waltham, MA, USA). Logarithms (base 10) of concentrations of copy numbers were prepared from 10 9 to 10 1 . The qPCR reaction was performed and obtained Ct values were converted to a standard curve by using GraphPad Prism 7.0 software (GraphPad Software, San Diego, CA, USA). The detection limit was 1000 copies of the ZIKV .....
    Document: To generate the ZIKV NS5 gene standard curve, a 105 bp ZIKV NS5 PCR amplicon was cloned into a pJET1.2 vector (Thermo Fisher, Waltham, MA, USA). Logarithms (base 10) of concentrations of copy numbers were prepared from 10 9 to 10 1 . The qPCR reaction was performed and obtained Ct values were converted to a standard curve by using GraphPad Prism 7.0 software (GraphPad Software, San Diego, CA, USA). The detection limit was 1000 copies of the ZIKV NS5 gene.

    Search related documents:
    Co phrase search for related documents
    • copy number and detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
    • copy number and GraphPad Prism: 1
    • copy number and qPCR reaction: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • copy number and standard curve: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • copy number concentration and Ct value: 1
    • copy number concentration and detection limit: 1, 2, 3
    • copy number concentration and GraphPad Prism: 1
    • Ct value and detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • Ct value and GraphPad Prism: 1, 2
    • Ct value and qPCR reaction: 1, 2, 3, 4, 5, 6, 7
    • Ct value and standard curve: 1, 2, 3, 4, 5
    • detection limit and GraphPad Prism: 1, 2, 3
    • detection limit and qPCR reaction: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • detection limit and standard curve: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • GraphPad Prism and obtain perform: 1
    • GraphPad Prism and standard curve: 1
    • GraphPad Prism and USA San Diego GraphPad Software software: 1, 2, 3, 4, 5, 6, 7, 8
    • qPCR reaction and standard curve: 1, 2, 3, 4, 5