Selected article for: "analytic specificity and plotted linearity"

Author: Hijano, Diego R.; Brazelton de Cardenas, Jessica; Maron, Gabriela; Garner, Cherilyn D.; Ferrolino, Jose A.; Dallas, Ronald H.; Gu, Zhengming; Hayden, Randall T.
Title: Clinical correlation of influenza and respiratory syncytial virus load measured by digital PCR
  • Document date: 2019_9_3
  • ID: 1sli4e5v_17
    Snippet: Analytic specificity for influenza A were 100%. Positive predictive value was 0.793 and negative predictive value was 0.818 (S1 Table) . Plotted linearity for influenza A had an R 2 value of 0.997 (S1 Fig). Within run variation ranged from 0.24% CV to 0.85% CV for the high external control, and from 0.42% CV to 0.64% CV for the low external control. Between run variation was 0.87% CV for the high control and 0.70% CV for the low control (S2 Table.....
    Document: Analytic specificity for influenza A were 100%. Positive predictive value was 0.793 and negative predictive value was 0.818 (S1 Table) . Plotted linearity for influenza A had an R 2 value of 0.997 (S1 Fig). Within run variation ranged from 0.24% CV to 0.85% CV for the high external control, and from 0.42% CV to 0.64% CV for the low external control. Between run variation was 0.87% CV for the high control and 0.70% CV for the low control (S2 Table) . For influenza A the limit of detection, limit of quantitation, and cutoff for positivity all coincided at 3.172 log 10 copies/mL (S1 Table) .

    Search related documents:
    Co phrase search for related documents
    • analytic specificity and high control: 1
    • analytic specificity and high control cv: 1
    • analytic specificity and influenza analytic specificity: 1
    • analytic specificity and influenza plotted linearity: 1
    • analytic specificity and low control: 1
    • analytic specificity and negative predictive value: 1
    • analytic specificity and plotted linearity: 1
    • analytic specificity and positive predictive value: 1
    • analytic specificity and positivity cutoff quantitation limit: 1
    • analytic specificity and predictive value: 1
    • analytic specificity and quantitation limit: 1
    • detection limit and low control: 1, 2
    • detection limit and ml log 10 copy: 1
    • detection limit and negative predictive value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • detection limit and plotted linearity: 1
    • detection limit and positive predictive value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • detection limit and positivity cutoff quantitation limit: 1
    • detection limit and predictive value: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
    • detection limit and quantitation limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12