Author: Turgeon, Nathalie; Hamelin, Marie-Ève; Verreault, Daniel; Lévesque, Ariane; Rhéaume, Chantal; Carbonneau, Julie; Checkmahomed, Liva; Girard, Matthieu; Boivin, Guy; Duchaine, Caroline
Title: Design and Validation with Influenza A Virus of an Aerosol Transmission Chamber for Ferrets Document date: 2019_2_19
ID: 1pcy24po_9
Snippet: The D50 diameters at a chamber flow rate of 400 L/min were 5.07 ± 0.18 µm and 6.36 ± 0.22 µm with 40 and 160 open orifices, respectively, and 7.8 ± 0.78 µm at 200 L/min with 160 open orifices ( Figure 6 ). To ensure correct air sampling, measurements were also made at 2" from the air exhaust of cage number three for validation purposes. The D50 values measured at 2" from air exhaust were the same (data not shown). Figure 6 . Particle separa.....
Document: The D50 diameters at a chamber flow rate of 400 L/min were 5.07 ± 0.18 µm and 6.36 ± 0.22 µm with 40 and 160 open orifices, respectively, and 7.8 ± 0.78 µm at 200 L/min with 160 open orifices ( Figure 6 ). To ensure correct air sampling, measurements were also made at 2" from the air exhaust of cage number three for validation purposes. The D50 values measured at 2" from air exhaust were the same (data not shown). Figure 6 . Particle separator D50 measurement as a function of airflow and the number of separator orifices used. Comparison of particle distribution in cage three with and without a particle separator, as measured with an aerodynamic particle sizer (APS) located at 2" from the particle separator.
Search related documents:
Co phrase search for related documents- aerodynamic particle sizer and APS aerodynamic particle sizer: 1, 2, 3, 4, 5, 6
- aerodynamic particle sizer and cage number: 1, 2
- aerodynamic particle sizer and cage particle distribution comparison: 1
- aerodynamic particle sizer and flow rate: 1
- aerodynamic particle sizer and particle distribution: 1, 2, 3
- aerodynamic particle sizer and particle distribution comparison: 1
- aerodynamic particle sizer and particle separator: 1, 2
- aerodynamic particle sizer and particle separator cage particle distribution comparison: 1
- aerodynamic particle sizer and particle sizer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- air exhaust and cage number: 1
- air exhaust and cage number air exhaust: 1
- air exhaust and correct air sampling: 1
- air exhaust and correct air sampling ensure: 1
- air exhaust and flow rate: 1, 2, 3, 4
- air exhaust and particle distribution: 1
- air sampling and cage number: 1
- air sampling and cage number air exhaust: 1
- air sampling and correct air sampling: 1
- air sampling and correct air sampling ensure: 1
Co phrase search for related documents, hyperlinks ordered by date