Author: Lee, Yun Ha; Jang, Yo Han; Kim, Young-Seok; Kim, Jinku; Seong, Baik Lin
                    Title: Evaluation of green tea extract as a safe personal hygiene against viral infections  Document date: 2018_1_8
                    ID: 07sn6d9r_11
                    
                    Snippet: The size distribution of influenza virus treated with GTE or PBS was measured by dynamic light scattering (DLS). 5 × 10 7 PFU/mL of PR8 virus was treated with 0.1% GTE or PBS for 24 h at 25°C. After the treatment, the virus samples were applied to the Particle size & Zeta potential Anlayzer (ELS-2000ZS, Otsuka Electronics, Japan). The size distribution was measured twice with accumulation time 200 in PBS solvent at 25°C. The morphology of the .....
                    
                    
                    
                     
                    
                    
                    
                    
                        
                            
                                Document: The size distribution of influenza virus treated with GTE or PBS was measured by dynamic light scattering (DLS). 5 × 10 7 PFU/mL of PR8 virus was treated with 0.1% GTE or PBS for 24 h at 25°C. After the treatment, the virus samples were applied to the Particle size & Zeta potential Anlayzer (ELS-2000ZS, Otsuka Electronics, Japan). The size distribution was measured twice with accumulation time 200 in PBS solvent at 25°C. The morphology of the virus treated with GTE was analyzed by cryo-electron microscopy (cryo-EM). Purified influenza viruses were loaded onto the Formvar Film 200 copper grid (Electron Microscopy Sciences). After 60 s of sample adsorption, the grid was negative stained with 1% uranyl acetate. Sample vitrification was performed using Vitrobot (FEI), and the vitrified sample was imaged using a CryoTecnai F20 transmission electron microscope (FEI).
 
  Search related documents: 
                                Co phrase  search for related documents- accumulation time and Particle size: 1, 2
  - copper grid and transmission electron: 1, 2, 3
  - copper grid and transmission electron microscope: 1, 2, 3
  - copper grid and uranyl acetate: 1, 2
  - copper grid and virus sample: 1
  - cryo electron and influenza virus: 1, 2, 3, 4, 5, 6
  - cryo electron and Particle size: 1, 2
  - cryo electron and sample vitrification: 1, 2
  - cryo electron and transmission electron: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
  - cryo electron and transmission electron microscope: 1
  - cryo electron and virus sample: 1
  - cryo electron and vitrified sample: 1
  - cryo em and influenza virus: 1, 2, 3, 4, 5, 6
  - cryo em and Particle size: 1, 2, 3
  - cryo em and size distribution: 1
  - cryo em and transmission electron: 1
  - cryo em and virus morphology: 1
  - cryo em and virus sample: 1
  - cryo em and vitrified sample: 1, 2
  
 
                                Co phrase  search for related documents, hyperlinks ordered by date