Author: Lu, Yujie; Liu, Wenjuan; Zhang, Man; Deng, Yanfang; Jiang, Min; Bai, Gang
Title: The Screening Research of NF-?B Inhibitors from Moutan Cortex Based on Bioactivity-Integrated UPLC-Q/TOF-MS Document date: 2019_3_3
ID: 1ahxau9k_7
Snippet: A Waters Acquity UPLC System (Waters Co., Milford, MA, USA) equipped with a photo diode array detector (PDAD) was used to analyze samples. The chromatographic column was an Acquity BEH C 18 -column (2.1 mm ×100 mm, 1.7 m; Waters Co.). The flow rate was 0.40 mL/min and the column temperature was maintained at 30 ∘ C. The test sample injection volume was 5 L. The optimal mobile phase was composed of A (0.1% formic acid in water) and B (acetonitr.....
Document: A Waters Acquity UPLC System (Waters Co., Milford, MA, USA) equipped with a photo diode array detector (PDAD) was used to analyze samples. The chromatographic column was an Acquity BEH C 18 -column (2.1 mm ×100 mm, 1.7 m; Waters Co.). The flow rate was 0.40 mL/min and the column temperature was maintained at 30 ∘ C. The test sample injection volume was 5 L. The optimal mobile phase was composed of A (0.1% formic acid in water) and B (acetonitrile) and the ratio was as follows: 0-1.0 min, 2% to 5% B; 1.0-2.0 min, 5% to 6% B; 2.0-4.0 min, 6% to 7% B; 4.0-6.0 min, 7% to 9% B; 6.0-9.0 min, 9% to 14% B; 9.0-12.0 min, 14% to 16% B; 12.0-18.0 min, 16% to 21% B; 18.0-21.0 min, 21% to 27% B; 21.0-22.0 min, 27% to 40% B.
Search related documents:
Co phrase search for related documents- column temperature and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9
- diode array detector and flow rate: 1, 2, 3
- diode array detector and formic acid: 1
- diode array detector and injection volume: 1
- diode array detector and mobile phase: 1, 2, 3
- flow rate and formic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17
- flow rate and injection volume: 1, 2, 3, 4, 5, 6
- flow rate and mobile phase: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39
- flow rate and sample analyze: 1, 2
- flow rate and test sample: 1, 2, 3
- flow rate and water formic acid: 1, 2, 3, 4
- formic acid and injection volume: 1, 2
- formic acid and mobile phase: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
- formic acid and water formic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
- injection volume and mobile phase: 1, 2, 3, 4
- injection volume and water formic acid: 1
- mobile phase and sample analyze: 1
- mobile phase and water formic acid: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- sample analyze and test sample: 1, 2, 3, 4, 5, 6, 7, 8
Co phrase search for related documents, hyperlinks ordered by date