Selected article for: "flow rate and injection volume"

Author: Lu, Yujie; Liu, Wenjuan; Zhang, Man; Deng, Yanfang; Jiang, Min; Bai, Gang
Title: The Screening Research of NF-?B Inhibitors from Moutan Cortex Based on Bioactivity-Integrated UPLC-Q/TOF-MS
  • Document date: 2019_3_3
  • ID: 1ahxau9k_7
    Snippet: A Waters Acquity UPLC System (Waters Co., Milford, MA, USA) equipped with a photo diode array detector (PDAD) was used to analyze samples. The chromatographic column was an Acquity BEH C 18 -column (2.1 mm ×100 mm, 1.7 m; Waters Co.). The flow rate was 0.40 mL/min and the column temperature was maintained at 30 ∘ C. The test sample injection volume was 5 L. The optimal mobile phase was composed of A (0.1% formic acid in water) and B (acetonitr.....
    Document: A Waters Acquity UPLC System (Waters Co., Milford, MA, USA) equipped with a photo diode array detector (PDAD) was used to analyze samples. The chromatographic column was an Acquity BEH C 18 -column (2.1 mm ×100 mm, 1.7 m; Waters Co.). The flow rate was 0.40 mL/min and the column temperature was maintained at 30 ∘ C. The test sample injection volume was 5 L. The optimal mobile phase was composed of A (0.1% formic acid in water) and B (acetonitrile) and the ratio was as follows: 0-1.0 min, 2% to 5% B; 1.0-2.0 min, 5% to 6% B; 2.0-4.0 min, 6% to 7% B; 4.0-6.0 min, 7% to 9% B; 6.0-9.0 min, 9% to 14% B; 9.0-12.0 min, 14% to 16% B; 12.0-18.0 min, 16% to 21% B; 18.0-21.0 min, 21% to 27% B; 21.0-22.0 min, 27% to 40% B.

    Search related documents:
    Co phrase search for related documents
    • array detector and diode array detector: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • array detector and flow rate: 1, 2, 3, 4, 5
    • array detector and formic acid: 1, 2
    • array detector and injection volume: 1, 2
    • array detector and mobile phase: 1, 2, 3, 4, 5, 6, 7
    • array detector and water formic acid: 1
    • chromatographic column and column temperature: 1
    • chromatographic column and flow rate: 1, 2, 3, 4
    • chromatographic column and formic acid: 1, 2, 3
    • chromatographic column and injection volume: 1
    • chromatographic column and mobile phase: 1, 2, 3, 4, 5, 6, 7
    • chromatographic column and water formic acid: 1
    • column temperature and diode array detector: 1
    • column temperature and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • column temperature and formic acid: 1
    • column temperature and injection volume: 1, 2
    • column temperature and mobile phase: 1, 2, 3, 4, 5, 6, 7, 8, 9
    • diode array detector and formic acid: 1
    • diode array detector and injection volume: 1