Selected article for: "electron microscope and transmission electron"

Author: Meier, Anita F.; Suter, Mark; Schraner, Elisabeth M.; Humbel, Bruno M.; Tobler, Kurt; Ackermann, Mathias; Laimbacher, Andrea S.
Title: Transfer of Anti-Rotavirus Antibodies during Pregnancy and in Milk Following Maternal Vaccination with a Herpes Simplex Virus Type-1 Amplicon Vector
  • Document date: 2017_2_16
  • ID: 09hmet7r_56
    Snippet: For negative staining, samples (see section "RVLP purification") were adsorbed to carbon-coated parlodion films mounted on 300 mesh/inch copper grids (Electron Microscopy Sciences (EMS), Fort Washington, PA, USA) for 10 min washed once with H 2 O, and stained with 2% phosphotungstic acid (PTA), pH 7.0 (Aldrich, Steinheim, Germany) for 1 min. Specimens were analyzed in a transmission electron microscope (CM12, Philips, Eindhoven, The Netherlands) .....
    Document: For negative staining, samples (see section "RVLP purification") were adsorbed to carbon-coated parlodion films mounted on 300 mesh/inch copper grids (Electron Microscopy Sciences (EMS), Fort Washington, PA, USA) for 10 min washed once with H 2 O, and stained with 2% phosphotungstic acid (PTA), pH 7.0 (Aldrich, Steinheim, Germany) for 1 min. Specimens were analyzed in a transmission electron microscope (CM12, Philips, Eindhoven, The Netherlands) equipped with a CCD camera (Ultrascan 1000, Gatan, Pleasanton, CA, USA) at an acceleration voltage of 100 kV.

    Search related documents:
    Co phrase search for related documents
    • acceleration voltage and copper grid: 1
    • acceleration voltage and mesh inch: 1
    • acceleration voltage and transmission electron: 1, 2, 3, 4
    • acceleration voltage and transmission electron microscope: 1, 2, 3, 4
    • ccd camera and copper grid: 1
    • ccd camera and mesh inch: 1
    • ccd camera and negative staining: 1
    • ccd camera and transmission electron: 1, 2, 3, 4, 5
    • ccd camera and transmission electron microscope: 1, 2, 3, 4, 5
    • copper grid and phosphotungstic acid: 1
    • copper grid and transmission electron: 1, 2, 3, 4
    • copper grid and transmission electron microscope: 1, 2, 3, 4
    • mesh inch and transmission electron: 1
    • mesh inch and transmission electron microscope: 1
    • negative staining and phosphotungstic acid: 1, 2, 3, 4
    • negative staining and PTA phosphotungstic acid: 1
    • negative staining and transmission electron: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
    • negative staining and transmission electron microscope: 1, 2, 3
    • phosphotungstic acid and transmission electron microscope: 1, 2, 3