Author: Gwon, Yong-Dae; Strand, Mårten; Lindqvist, Richard; Nilsson, Emma; Saleeb, Michael; Elofsson, Mikael; Överby, Anna K.; Evander, Magnus
Title: Antiviral Activity of Benzavir-2 against Emerging Flaviviruses Document date: 2020_3_22
ID: 0ym40eki_16
Snippet: After incubation, the medium was removed, and cells were fixed with 4% paraformaldehyde for 1 h at room temperature and washed with phosphate-buffered saline (PBS). The fixed cells were counterstained with 300 nM 4 ,6-diamidino-2-phenylindole (DAPI) in PBS. The Trophos plate runner HD ® (Trophos, Roche Group, Basel, Switzerland) identified all individual ZsGreen-expressing cells or DAPI-stained cells and quantified the fluorescence intensity in .....
Document: After incubation, the medium was removed, and cells were fixed with 4% paraformaldehyde for 1 h at room temperature and washed with phosphate-buffered saline (PBS). The fixed cells were counterstained with 300 nM 4 ,6-diamidino-2-phenylindole (DAPI) in PBS. The Trophos plate runner HD ® (Trophos, Roche Group, Basel, Switzerland) identified all individual ZsGreen-expressing cells or DAPI-stained cells and quantified the fluorescence intensity in each well. The infection rates were calculated by dividing the number of infected cells (ZsGreen-expressing cells) to the total number of cells (DAPI-stained cells). The EC 50 values were calculated by non-linear regression analysis with a variable slope, using GraphPad Prism 7.0 software. Furthermore, the EC 90 values were calculated by Quick → Calcs, which is provided at GraphPad website [25] 2.6. Cell Toxicity Assay
Search related documents:
Co phrase search for related documents- fluorescence intensity and GraphPad Prism: 1, 2
- fluorescence intensity and infected cell: 1, 2, 3, 4, 5
- fluorescence intensity and infection rate: 1
- fluorescence intensity and room temperature: 1, 2, 3, 4, 5, 6, 7, 8
- GraphPad Prism and infected cell: 1, 2
- GraphPad Prism and non linear variable slope regression analysis: 1
- GraphPad Prism and phosphate buffer: 1
- GraphPad Prism and regression analysis: 1, 2, 3, 4, 5, 6, 7, 8
- GraphPad Prism and room temperature: 1, 2, 3, 4, 5, 6, 7, 8, 9
- infected cell and room temperature: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
- infection rate and regression analysis: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
- infection rate and room temperature: 1, 2, 3
- medium remove and room temperature: 1, 2, 3
- non linear variable slope regression analysis and regression analysis: 1
- PBS phosphate buffer saline and phosphate buffer: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
- PBS phosphate buffer saline and phosphate buffer saline: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
- PBS phosphate buffer saline and room temperature: 1, 2, 3, 4, 5
- phosphate buffer and room temperature: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18
- phosphate buffer saline and room temperature: 1, 2, 3, 4, 5, 6, 7
Co phrase search for related documents, hyperlinks ordered by date