Selected article for: "flow rate and light scatter"

Author: Amy V Mueller; Loretta A Fernandez
Title: Assessment of Fabric Masks as Alternatives to Standard Surgical Masks in Terms of Particle Filtration Efficiency
  • Document date: 2020_4_22
  • ID: mnjy6bq2_9
    Snippet: Particle counters. Particles in ambient air and air inside of the masks were simultaneously counted using two PortaCount Plus Model 8028 instruments running in count mode. The PortaCount Plus instruments use condensation particle counters (CPCs), which nucleate alcohol droplets from the smaller sampled particles. The larger alcohol droplets can then be counted using a light scatter detector (consisting of pumps to control flow rate, a laser, focu.....
    Document: Particle counters. Particles in ambient air and air inside of the masks were simultaneously counted using two PortaCount Plus Model 8028 instruments running in count mode. The PortaCount Plus instruments use condensation particle counters (CPCs), which nucleate alcohol droplets from the smaller sampled particles. The larger alcohol droplets can then be counted using a light scatter detector (consisting of pumps to control flow rate, a laser, focusing elements, and a photodetector). Each PortaCount samples at a flow rate of 1.67 cm 3 /s and reports the number of particles per cubic centimeter, P, of air sampled each second as All rights reserved. No reuse allowed without permission. author/funder, who has granted medRxiv a license to display the preprint in perpetuity.

    Search related documents:
    Co phrase search for related documents
    • air ambient air and flow rate: 1
    • air ambient air and mask inside air ambient air particle: 1, 2
    • air ambient air particle and ambient air: 1
    • air ambient air particle and mask inside air ambient air particle: 1
    • ambient air and condensation particle counter: 1
    • ambient air and flow rate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
    • ambient air and mask inside air ambient air particle: 1, 2
    • ambient air and particle counter: 1, 2, 3, 4
    • condensation particle counter and cpc condensation particle counter: 1, 2
    • condensation particle counter and particle counter: 1, 2, 3
    • cpc condensation particle counter and particle counter: 1, 2
    • flow rate and particle counter: 1, 2, 3