Author: Turgeon, Nathalie; Hamelin, Marie-Ève; Verreault, Daniel; Lévesque, Ariane; Rhéaume, Chantal; Carbonneau, Julie; Checkmahomed, Liva; Girard, Matthieu; Boivin, Guy; Duchaine, Caroline
Title: Design and Validation with Influenza A Virus of an Aerosol Transmission Chamber for Ferrets Document date: 2019_2_19
ID: 1pcy24po_5
Snippet: The aerosol distribution was measured either with or without the particle separator between cages number two and three at flow rates of 200 L/min and 400 L/min. Measurements were also taken at 400 L/min with 75% of the orifices from the particle separator blocked with masking tape, leaving only 40 orifices open for the passage of air......
Document: The aerosol distribution was measured either with or without the particle separator between cages number two and three at flow rates of 200 L/min and 400 L/min. Measurements were also taken at 400 L/min with 75% of the orifices from the particle separator blocked with masking tape, leaving only 40 orifices open for the passage of air.