Selected article for: "analytical sensitivity and detection limit"

Author: Moore, Matthew D.; Jaykus, Lee-Ann
Title: Development of a Recombinase Polymerase Amplification Assay for Detection of Epidemic Human Noroviruses
  • Document date: 2017_1_9
  • ID: 03a6hq3t_5
    Snippet: To test the analytical sensitivity (detection limit) of the RT-RPA assay, serial dilutions of purified GII.4 New Orleans RNA from three patients (isolates 29, 47, and 58) were tested for 8 replicates and probit regressions used to interpolate a limit of detection (Fig. 2 ). The range of input RNA producing consistently positive results for all three replicates was 3.2 to 6.2 LGC with time to threshold florescence of 12.4 ± 2.4 min to 8.2 ± 0.5 .....
    Document: To test the analytical sensitivity (detection limit) of the RT-RPA assay, serial dilutions of purified GII.4 New Orleans RNA from three patients (isolates 29, 47, and 58) were tested for 8 replicates and probit regressions used to interpolate a limit of detection (Fig. 2 ). The range of input RNA producing consistently positive results for all three replicates was 3.2 to 6.2 LGC with time to threshold florescence of 12.4 ± 2.4 min to 8.2 ± 0.5 min, respectively. Based on the probit regressions average, the limit of detection of the assay (the level of input RNA for which 95% of samples would be positive) is 3.40 ± 0. 20 LGC. This is about 1.0 LGC higher than the limit of detection determined for RT-qPCR, which was predicted by probit to be 2.3 ± 0.04 LGC.

    Search related documents:
    Co phrase search for related documents
    • analytical sensitivity and assay detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21
    • analytical sensitivity and detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • analytical sensitivity and detection limit analytical sensitivity: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
    • analytical sensitivity and probit regression: 1, 2, 3, 4
    • assay detection and detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • assay detection and detection limit analytical sensitivity: 1, 2, 3, 4, 5, 6
    • assay detection and min florescence: 1
    • assay detection and probit regression: 1, 2, 3, 4
    • assay detection limit and detection limit: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25
    • assay detection limit and detection limit analytical sensitivity: 1, 2, 3, 4
    • assay detection limit and min florescence: 1
    • detection limit and min florescence: 1
    • detection limit and probit regression: 1, 2, 3, 4, 5