Selected article for: "door operation and passage door operation"

Author: Saarinen, Pekka E.; Kalliomäki, Petri; Tang, Julian W.; Koskela, Hannu
Title: Large Eddy Simulation of Air Escape through a Hospital Isolation Room Single Hinged Doorway—Validation by Using Tracer Gases and Simulated Smoke Videos
  • Document date: 2015_7_7
  • ID: 15oi1wza_58
    Snippet: A very large air flow rate without creating a draughty environment can be attained by using downward ventilation with large supply area [24] . Guidelines for isolation rooms do not recommend any particular ventilation strategy, but require keeping the room at negative pressure differential [40] . Kim and Augenbroe [41] suggest satisfying this by adaptive VAV (Variable Air Volume) operation, normally maintaining a low negative pressure differentia.....
    Document: A very large air flow rate without creating a draughty environment can be attained by using downward ventilation with large supply area [24] . Guidelines for isolation rooms do not recommend any particular ventilation strategy, but require keeping the room at negative pressure differential [40] . Kim and Augenbroe [41] suggest satisfying this by adaptive VAV (Variable Air Volume) operation, normally maintaining a low negative pressure differential, but temporarily inducing a higher value prior to door operation, to reduce energy consumption. As demonstrated by Adams et al [42] , containment failure during door operation and passage can be significantly reduced by applying pressure difference. Even though the pressure differential immediately disappears when the door is opened, the supply and exhaust air flow differential, used to generate the underpressure in the isolation room, remains and works against the flow escaping from the isolation room.

    Search related documents:
    Co phrase search for related documents
    • air flow and door open: 1
    • air flow and door operation: 1
    • air flow and energy consumption: 1, 2, 3, 4, 5, 6, 7, 8
    • air flow and energy consumption reduce: 1, 2
    • air flow and exhaust air flow differential: 1
    • air flow and exhaust air flow differential supply: 1
    • air flow and flow work: 1, 2, 3
    • air flow and high value: 1
    • air flow and isolation room: 1, 2, 3, 4, 5, 6, 7, 8
    • air flow differential and exhaust air flow differential: 1
    • air flow differential and exhaust air flow differential supply: 1
    • air flow differential and isolation room: 1
    • air flow rate and energy consumption: 1, 2, 3, 4
    • air flow rate and energy consumption reduce: 1
    • air flow rate and exhaust air flow differential: 1
    • air flow rate and exhaust air flow differential supply: 1
    • air flow rate and isolation room: 1, 2, 3, 4
    • containment failure and door open: 1
    • containment failure and door operation: 1, 2